The liquid density and specific gravity balance is based on Archimedes' principle, calculating liquid density by measuring the weight difference of an object in air and liquid. It is used for concentration detection and quality control in industries such as coatings and inks, enabling quick assessment of raw material ratios and product consistency.
Selection
When selecting, consider matching measurement accuracy with sample characteristics; the balance's range must cover commonly used density ranges. Pay attention to temperature compensation features and calibration methods, and ensure the operation interface is simple and easy to read. Determine the level of automation based on the frequency of testing, and adapt to industry-standard container specifications.

Terms

Standards

Instruments

Made of stainless steel to ensure durability, equipped with hollow structure Balance hammer filled with lead particles to adjust weight, Cup volume 100ml in line with national standards design, suitable for a variety of liquid specific gravity determination.

$ 106.00

Using 5cm ³ standard measurement hammer volume, the accuracy of 0.001g, through the V-shaped groove placed riding code recovery equilibrate, can quickly and accurately measurement of liquid specific gravity.

$ 193.00

50Ml volume stainless-steelbeaker body, equipped with hollow structure Balance hammer filled with lead particles to adjust the weight, in line with national standards designed to ensure measurement accuracy, suitable for a variety of liquid specific gravity detection.

$ 106.00

Using Electromagnetic Force Sensor to ensure data accuracy, density Measurement range 0~ 10g/cm ³, resolution 0.0001g/cm ³, large sink glass to reduce errors, built-in a variety of liquid density values, under the dish weighing design anti-spill.

$ 754.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeter customization are supported, and RS232 interface is standard to realize data direct transmission.

$ 587.00

Made of stainless steel, the Cup has a volume of 50 ml and can withstand an internal pressure of 10.3 bar. It is suitable for the determination of specific gravity of various Coatings and auxiliary materials. It is easy to operate and meets international standards.

$ 128.00

High Accuracy Strain Gauge Sensor for measurement of solid density, volume and specific gravity based on Archimedes law, large stainless steel square and LED/LCD display.

$ 211.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading function response time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, standard RS232 interface supports data direct transmission.

$ 845.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, standard RS232 interface supports data direct transmission.

$ 457.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeter customization are supported, and RS232 interface is standard for data transmission.

$ 935.00

With 0.001g/cm ³ density accuracy and 0.01g readability, support solid liquid density test, built-in density reference table can directly display the results, configure the battery to realize mobile measurement.

$ 332.00

Using copper nickel plating material, volume 37ml, in line with GB/T6750 standard, equilibrium hammer is hollow structure and filled with lead particles to adjust the weight, suitable for Coating and auxiliary materials, oil and other liquids specific gravity determination.

$ 106.00

Using aluminum material, hollow structure design, volume 50ml, in line with the national standard GB/T6750, suitable for density measurement, Balance hammer filled with lead particles to adjust the weight.

$ 106.00

Made of aluminum alloy material, volume 37ml, measuring temperature 23 ℃, designed according to national standards, can be calculated in stages to ensure long-term Measurement accuracy, suitable for liquid Coating density determination.

$ 112.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.