Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.
Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.
Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.
Aluminum block Bathroom heat transfer uniformity, temperature control accuracy of +/- 0.5 ℃, 36 holes independent air needle channel can avoid cross-contamination, lifting stroke 200mm easy to operate, gas flow 0-15L/min adjustable.
Aluminum block Bathroom heat transfer uniform heating, temperature control accuracy +/- 0.5 ℃, gas flow rate 0-15L/min adjustable, blow pipe independent to avoid cross-contamination, to achieve rapid oxygen-free condensing.
The aluminum block Bathroom is used for uniform heat transfer, rapid and accurate temperature control, temperature control accuracy of +/- 0.5 ° C, display accuracy of +/- 0.1 ° C, gas flow rate of 0~ 15L/min, blow pipe to avoid cross-contamination independently, lifting stroke of 200mm.
Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.
Double needle automatic switching angle to improve condensing efficiency, support 1-8 bit Sample Handling, temperature control accuracy of +/- 0.5 ℃, with independent nitrogen channel and overheating protection to ensure safe and stable operation.
Using purge and trap technology, the temperature control accuracy can reach +/- 0.5 ℃, 12 samples can be processed simultaneously, and the nitrogen consumption can be adjusted at 330ml/min/sample to achieve rapid anaerobic condensation.
Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, support 36 samples at the same time, nitrogen consumption can be adjusted to 330ml/min/sample, digital temperature control to ensure accurate and reliable operation.
Colorimetric measurement based on Nasler method, Measurement range 0.00-10 mg/L, providing 100 tests, accurate determination of ammonia nitrogen concentration by Color intensity change.
Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.
Using Dynamic Low Temperature Nitrogen Adsorption Method and High Sensitivity Sensor, the test range from 0.0005m ²/g has no upper limit, the repeatability error ≤ +/- 3%, and the single sample test is completed in about 3 minutes.
Using industrial grade Sensor to detect nitrogen dioxide gas, range 0~ 20ppm, resolution 0.1ppm, Response Time T90 < 60s, with waterproof, dustproof and explosion-proof characteristics, small and durable.