Adhesive Humidity and Heat Test Chamber

The adhesive damp heat test chamber simulates high-temperature and high-humidity environments through its heating and humidification system, allowing specimens to be continuously exposed under constant temperature and humidity conditions. This equipment is used to test the durability, changes in adhesive strength, and aging characteristics of adhesives in damp heat environments, commonly employed in adhesive product development and quality control processes.
Selection
When selecting a humidity and heat testing chamber for adhesives, considerations should include the temperature and humidity range and fluctuation, corrosion resistance of the inner chamber material, volume compatibility with sample dimensions, control accuracy and uniformity, safety protection features, and energy consumption standards. A comprehensive evaluation should be conducted based on specific testing requirements and budget constraints.

Terms

Standards

Instruments

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.

$ 2457.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Adopt TMHM equilibrate Conditioning method, temperature fluctuation +/- 1.0 ℃, humidity deviation +/- 3% RH; with 100 sets of program capacity and P.I.D automatic calculation function, ensure stable and uniform heat preservation Humidity, support multi-stage programmable operation.

$ 2841.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.

$ 5705.00

Adopt equilibrate Conditioning Control system, Temperature Humidity range -60~ 150 ℃, 20~ 98% RH, Equipped with imported Compressor and environmentally friendly refrigerant, High Accuracy and stable operation. Special air circulation design ensures uniformity, built-in multiple protection functions, prolong equipment life.

$ 3640.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Adopt fluorine-free environmental protection design, Humidity Control Range 35-95% RH, input Power 2300W, with PID automatic calculation function, ensure accurate and stable thermal insulation Humidity control, equipped with multiple Safety protection systems.

$ 5405.00

Using French Taikang fully enclosed Compressor, Temperature Fluctuation ≤ +/- 0.5 ℃, Humidity deviation + 2, -3% RH, with 100 sets of program capacity and RS-232/485 communication interface, improve test accuracy and convenience.

$ 10804.00

Articles

Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Application of Initial Tack Tester in the Detection of Pressure-Sensitive Hot Melt Adhesives
The initial tack tester is a device used to measure the initial adhesive properties of pressure-sensitive hot melt adhesives, primarily by employing the rolling ball method or probe method to assess the adhesive force at the moment of contact.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Sag resistance and leveling in constructability evaluation
This article primarily discusses how to balance the two key properties of sag resistance and leveling during the application of materials such as coatings and adhesives. Sag resistance refers to the material's ability to resist sagging due to gravity on vertical surfaces, while leveling refers to the material's ability to automatically smooth out its surface after application.
Tensile testing machine for testing the tensile shear strength of adhesives
This article introduces the method for testing the tensile shear strength of adhesives using a tensile testing machine. Tensile shear strength is a key indicator for evaluating the mechanical properties of adhesives. During the test, a bonded standard specimen is clamped into the testing machine and stretched at a constant speed until failure. The maximum load is recorded, and the strength is calculated accordingly.