Torque Calibration Meter

The torque calibrator measures the torque value of rotating tools through sensors and compares it with standard values for calibration. It is used to test the torque accuracy of tools such as screwdrivers and wrenches, ensuring that assembly operations meet specified requirements.
Selection
When selecting, consider the range covering common torque values, ensuring accuracy meets process tolerances and compatibility with common tool interfaces. Pay attention to temperature stability and long-term repeatability, ensure the operation interface is clear and easy to read, and verify the validity of the calibration certificate.

Terms

Standards

Instruments

Two-way calibration accuracy of 0.5 level, support three units of automatic conversion and three test modes, can store 99 sets of data and automatically calculate statistical values, equipped with mechanical overload protection.

$ 696.00

With 0.5 accuracy and two-way calibration function, it supports three automatic unit conversion and three test modes, can store 99 sets of data and automatically calculate statistical values, and is equipped with mechanical overload protection to ensure Sensor safety.

$ 696.00

With 0.5 accuracy and two-way calibration function, support three automatic unit conversion and three test modes, can store 99 sets of data and automatically calculate statistical values, equipped with upper and lower limit comparison and sound alarm function.

$ 696.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

With auto calibration function, measurement range 0.1~ 200GU, repeability +/- 0.5GU, can store 254 sets of data, support USB and Bluetooth output, lightweight and portable.

$ 198.00

LCD backlight display for easy reading, Automatic calibration to ensure accuracy, weighing range 500g, readability 0.01g, AC and DC dual-use to adapt to a variety of environments.

$ 306.00

With 0.01g Readability and Automatic calibration function, support AC and DC dual-use and full scale peeling, LCD backlight display is clear, Draft Shield design is stable, suitable for a variety of environments.

$ 214.00

With 0.01pH accuracy and -5.0~ 105.0 ℃ Temperature Measurement range, support multi-point Automatic calibration and automatic temperature compensation, adapt to harsh environment.

$ 364.00

Adopt 0.5% F.S. High Accuracy torque Sensor, support bi-directional torque test and 400 sets of Data storage, with locking force and opening force dual Measurement mode and peak hold function, to meet the needs of a variety of Encasement container testing.

$ 1106.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 200GU, Repeatability +/- 0.5GU; Lightweight and portable, Automatic calibration, fast measurement, can store 254 sets of data, support USB, RS-232 and Bluetooth output.

$ 191.00

Using electronic Sensor technology, the accuracy level reaches 0.5, supports three automatic unit conversion and multiple test modes, can store 99 sets of data and automatically calculate statistical values.

$ 696.00

Weighing range 6000g, Readability 0.1g, with Automatic calibration and counting function, Stabilization time ≤ 3s, support full range peeling operation.

$ 212.00

Articles

Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
The cone and plate viscometer measures the rheological properties of a small amount of ink sample.
A cone-plate viscometer measures torque through rotation between the cone and plate, enabling the analysis of rheological properties with small ink samples. It is suitable for small-volume measurements, reducing interference from solvent evaporation.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.
The rotational viscometer reads the viscosity of ink.
A rotational viscometer measures viscosity by generating torque through a rotor rotating in the ink, aiding in the analysis of the ink's flow characteristics. The thickness or thinness of the ink affects printing quality, and both excessive thickness and excessive thinness can lead to issues.
Key Points for Measuring the Viscosity of Resin Solution with a Rotational Viscometer
When measuring the viscosity of resin solution with a rotational viscometer, it is based on the principle of internal friction, and the viscosity is calculated from the torque generated by the rotation of the rotor.
Rotational Viscometer vs. Stormer Viscometer: How to Choose the Right Instrument Based on Coating Type
The rotational viscometer measures viscosity by detecting rotor torque and can analyze rheological properties at different shear rates, making it suitable for research and precise measurements. The Stormer viscometer uses the load at a fixed rotational speed to determine the KU value, simulating construction conditions, and is commonly used for rapid on-site evaluation of coating application performance.
Application of Stormer Viscometer KU Value in Coating Viscosity Control
This article introduces the application of KU values measured by the Stormer viscometer in the coatings industry. The KU value reflects the viscosity of coatings by measuring the torque at a specific rotational speed, with higher numbers indicating greater viscosity.