Suitable for inner paper tube testing with an outer diaMeter of 400mm, with a capacity of 500kg and an adjustable speed of 10-80mm/min, it automatically judges the crushing force and supports data printing function.
Double shell structure with Air-Cooled system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃ and equipped with corundum tube to ensure high temperature Stability.
Equipped with 40 0.2ml independent tube positions, compatible with 8 * 0.2 tubes, high-quality materials are used to ensure sample safety and easy operation.
Double shell structure with cold air system to achieve rapid cooling, 51 program temperature control system to ensure +/- 1 ℃ accuracy, the highest Operating temperature of 1700 ℃, corundum Furnace tube high temperature performance.
The 54-hole design is suitable for 0.5ml centrifuge tube, with a maximum temperature tolerance of 100 ° C. A variety of thermostatic modules can be selected to achieve accurate temperature control to meet various experimental needs.
Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.
U-tube countercurrent design, viscosity measurement range of 200-1000cSt, accurate measurement based on the principle of liquid flow time in capillary tubing is proportional to viscosity.
Using 90 ° Measurement Angles and magnetic Induction principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures measurement accuracy and Stability.
Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.
Equipped with 2kw lamp tube to achieve instant curing, the transmission speed is adjustable from 1 to 7m/min, the irradiation distance is 100 to 200mm, the feed height is adjustable from 0 to 90mm, and the mesh belt width is 200mm, which can adapt to different pRoduction needs.
U-tube countercurrent design, Measurement range 20-100cSt, based on the principle of liquid flow time in capillary tubing is proportional to viscosity to ensure measurement accuracy and Repeatability.
U-tube countercurrent design, according to BS/IP/RF standard, viscosity measurement range covering 600 to 3000cSt, based on the principle of capillary method to ensure that the liquid flow time in the upright tube is proportional to the kinematic viscosity.
U-tube countercurrent design, viscosity measurement range 0.6-3 cSt, accurate determination of liquid kinematic viscosity based on capillary tubing principle, suitable for a variety of liquid samples.
Using U-tube vibration principle, only 2-3ml sample can complete the measurement, measurement Precision up to +/- 0.0008g/cm ³, built-in Peltier temperature control device to ensure temperature control accuracy.
U-shaped tube design, viscosity measurement range of 200-1000cSt, based on the principle of capillary tubing can accurately determine the kinematic viscosity of liquids at constant temperature.