Modular stainless steel vacuum circuit design ensures high Vacuum Level, metal dewar bottle to maintain constant liquid nitrogen temperature. Equipped with High Accuracy Sensor and 22-bit AD converter, aperture analytical range 3.5 to 5000 Angstroms, support DFT and MC theoretical model calculations.
With two movements of reciprocating and top-beating vibration, the screening efficiency is high and does not block the screen surface. It can be adapted to a set of screening screens of Φ 200, Φ 75, and Φ 100. The number of swirl/spins is 290 +/- 6 times/minute, and the number of beats is 156 +/- 3 times.
The use of hardened steel double-channel structure ensures dimensional stability, with a range of 0-100 μm and 10 μm Graduation, the film can be scraped in 3 seconds and the particle distribution can be evaluated.
Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.
Test range 0.5~ 3000μm, Maximum magnification 4000 times, can analyze the number of particles, area, circumference, diaMeter, aspect ratio and other distribution data, support a variety of formats of test report output.
Temperature range RT + 0~ 60 ℃, Temperature Fluctuation +/- 1%, using fluorine-free R134a refrigerant and mirror stainless steel liner to ensure energy saving, environmental protection and uniform temperature distribution.
The static capacity method is used for testing, with a specific surface area ranging from 0.01 m2/g to no upper limit, and a pore size analysis of 3.5 to 5000 angstroms. The modular stainless steel gas circuit design ensures a high vacuum, and the metal dewar bottle maintains a constant temperature. It supports a variety of theoretical model calculations.
The static capacity method is used to test the principle, the aperture analytical range is 3.5 to 5000 angstroms, and it is equipped with a modular stainless steel vacuum gas circuit and a metal dewar bottle, which supports DFT and MC theoretical model calculations.
Using French Taikang Compressor and PID automatic calculation technology, Temperature Fluctuation ≤ +/- 0.5 ℃ and uniformity ≤ +/- 2 ℃, multi-wing air supply circulation ensures no dead angle temperature field stability.
Equipped with 400 * 300mm curing area, using 36nm main peak wavelength and 350~ 450nm wide band Illuminant, the lamp board height can be customized to adjust 20mm, and supports independent control of aviation plugs.
Mirror stainless steel liner easy to clean, Temperature Uniformity +/- 1.5 ℃, support 0~ 60 ℃ wide range of temperature control, with over-temperature alarm and timing function, suitable for a variety of microbial foster.
Using fluorine-free refrigeration technology, temperature control accuracy of +/- 0.5 ℃, mirror stainless steel liner is easy to clean, support 1-9999 minutes timing function, to ensure a stable and efficient experimental environment.
Programmable setting of 3 to 12 beats per second and 1 second to 100 minutes homogenization time, equipped with 4.3-inch touchscreen and voice alarm function, effectively separates microbial components in solid samples and prevents cross-contamination.
Pore volume of 4.3cm ³/m ² ensures even distribution of inks and efficient transfer for High Accuracy printing applications.
The use of hardened steel to ensure dimensional stability, double-channel design can be measured in the range of 0-15μm, Graduation 1.5μm, scraper Travel 1-2 seconds to complete, 3 seconds to read the fineness value, easy and fast operation.