Vacuum Low Temperature Drying Oven

Vacuum low-temperature drying ovens reduce the boiling point by creating a vacuum and combine it with heating to rapidly dehydrate materials at low temperatures. They are used for drying heat-sensitive substances, such as pharmaceuticals, food products, and chemical raw materials, to avoid component degradation caused by high temperatures.
Selection
When selecting, focus on matching the vacuum range with material requirements, ensuring temperature control accuracy meets process demands, consider the corrosion resistance of the chamber material, design observation windows and sample racks for ease of operation, and ensure interface sizes are compatible with existing equipment.

Terms

Standards

Instruments

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

Equipped with programmed vacuum cycle function, drying time is shortened by more than 50%, temperature control accuracy +/- 1 ℃, support 7 groups of 63-step Program settings, digital Vacuum Level control accuracy +/- 1%.

$ 10937.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

The vacuum environment is used to reduce the boiling point of the liquid, the drying temperature can be as low as room temperature + 10 ℃, the Vacuum Level is 133Pa, the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, and the double-decked Glass door is easy to observe and can be filled with inert gas.

$ 6851.00

Vacuum environment can reduce the boiling point of liquid, suitable for drying heat sensitive substances, Vacuum Level < 133Pa, temperature control accuracy +/- 0.5 ℃, effectively shorten the drying time and prevent sample oxidation or explosion.

$ 1208.00

The digital vacuum Gauge is used to automatically control the Vacuum Level, with an accuracy of +/- 1%; the heating element is located in the Shelf of the box to shorten the heating time by 50%; the special aluminum shelf conducts heat quickly and does not oxidize at high temperature, effectively improving the drying efficiency.

$ 1655.00

The cuboid studio improves the volume utilization rate, the Vacuum Level control range is 10~ 105Pa accuracy +/- 1%, the programmed vacuum cycle accelerates the drying, and the 7 groups of 63-step programmable temperature control realize the whole process control.

$ 2762.00

Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.

$ 1003.00

The digital pressure sensor is used to automatically control the Vacuum Level, with accuracy +/- 1%; the programmed vacuum cycle can shorten the drying time by more than 50%; 7 groups of 63-step temperature programming realize the control of the rising and cooling rate, and the studio stainless steel material is durable and easy to clean.

$ 3690.00

The drying time is shortened by more than 50%, the Vacuum Level range is 10~ 105Pa, the temperature control accuracy is +/- 1 ℃, and the programmed vacuum cycle and 7 groups of 63-step temperature programming are provided to support inert gas environment operation.

$ 4419.00

The digital pressure sensor is used to automatically control the Vacuum Level with accuracy +/- 1%; the programmed vacuum cycle can shorten the drying time by more than 50%; 7 groups of 63-step programmable temperature control support slope mode to achieve accurate heating and cooling rate control.

$ 3690.00

Adopt microcomputer temperature control technology, temperature control accuracy +/- 1% ℃, Vacuum Level < 133pa, equipped with tempered Glass door and silicone sealing strip, support inert gas filling, suitable for rapid drying of complex ingredients.

$ 3462.00

With programmed vacuum cycle control, maximum cycle 99 times, Vacuum Level range of 10~ 105Pa, temperature control accuracy +/- 1 ℃, drying time is shortened by more than 50% compared with traditional equipment, support slope mode temperature programming.

$ 5700.00

Vacuum environment can reduce the boiling point of liquid, suitable for heat-sensitive substances; Vacuum Level < 133Pa effectively shortens the drying time; Microcomputer PID control ensures temperature accuracy +/- 0.5 ℃, Explosion-proof Glass door is easy to observe.

$ 611.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Vacuum adsorption coating of perovskite precursors on flexible substrates.
This article introduces the process of vacuum adsorption coating for perovskite precursors on flexible substrates.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.