Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
The equipment temperature range -40~ 70 ℃, Humidity Measurement range 20%~ 90% RH, temperature error +/- 1 ℃, using the principle of electrical change capacitance or resistance to achieve fast and accurate measurement, portable design only weighs 114g.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.
With split Probe design, Temperature Measurement range covering -10~ 50 ℃, can be extended to 1000 ℃, Humidity Measurement range 5~ 98% RH, error +/- 1.5 ℃ and +/- 5%, support unit conversion, portable and durable.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.
Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.
Humidity measurement range -10~ 60 ℃ and 10~ 95% RH, Sampling time 0.4 seconds, Automatic recording MAX Maximum, MIN Minimum and Final Measured value, Built-in Sensor and support USB data output.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.
Microcomputer and anti-interference technology implementation of rapid precision measurement, temperature range -10~ 60 ℃ error +/- 0.5 ℃, humidity range 10~ 95% RH error 2.5% +/- 1%, automatic memory MAX Maximum MIN Minimum and final measurement value.
With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.
Adopt microcomputer temperature and humidity controller, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with mirror stainless steel liner and observation window, support programmable control and multiple safety protection functions.
Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.