Ultrapure Water Purification System

Ultrapure water systems remove impurities from water through pretreatment, reverse osmosis, deionization, and ultrafiltration. The produced water is used for laboratory analysis, reagent preparation, and cleaning precision instruments, ensuring that impurities do not interfere with experimental results.
Selection
When selecting, consider water usage standards, daily demand, water source quality, and space dimensions. Verify parameters such as resistivity and total organic carbon, and pay attention to the replacement cycle of consumables as well as operation and maintenance costs.

Terms

Standards

Instruments

The water pRoduction rate reaches 5L/h, the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, the desalination and sterilization rate is over 99%, supports intelligent control and a variety of water intake modes, suitable for laboratory environment use.

$ 3543.00

The water pRoduction rate is 10L/h, and the eight-stage purification system includes reverse osmosis (RO) membrane and ultra-pure polishing column, providing 18.25MΩ. cm ultra-pure water quality, supporting multiple water intake modes and intelligent control functions.

$ 4027.00

The eight-stage deep purification system ensures that the water quality is pure, the resistivity of the pRoduced water is 18.25MΩ .cm, and it is equipped with an intelligent Control system to realize automatic monitoring and a variety of water intake modes to meet the strict experimental requirements.

$ 4511.00

Suitable for ultra-low conductivity water sample measurement, Glass grinder liquid interface design, pH Measurement range 0-11, Temperature range 0-80 ℃, support can add liquid reference solution.

$ 273.00

With 80L/H water pRoduction capacity and 18.2MΩ · cm ultra-pure water quality, it supports regular automatic circulation and consumable life monitoring. It can disinfect and display three-way water quality with one click, prolong the service life of the ultra-pure water bag, and achieve efficient online monitoring.

$ 2834.00

With 40L/H water pRoduction capacity and 18MΩ · cm resistivity ultrapure water output, the 7-inch touchscreen displays three-way water quality and temperature in real time, supports automatic circulation, consumables reminder and disinfection functions, ensuring stable water quality and low bacterial contamination.

$ 4408.00

With five-point pH automatic calibration and USP standard conductivity analysis, support linear nonlinear temperature compensation, Data storage up to 50,000/group, Capacitive touch interface easy to operate.

$ 2211.00

The water pRoduction rate reaches 5L/h, the water intake Flow velocity is 0.8L/min, and the RO membrane intelligent anti-scale flushing and automatic domestic circulation system are supported to ensure the stability of ultrapure water quality, which is suitable for a variety of experimental needs.

$ 1897.00

The resistivity of the pRoduced water is greater than 18.2MΩ · cm, the water pRoduction capacity is up to 100L/H, and it is equipped with a 5.1-inch LCD screen to display water quality and temperature in real time. It supports automatic circulation and disinfection functions, effectively prolonging the life of consumables.

$ 3097.00

Temperature range from room temperature to 60 ℃, temperature control accuracy +/- 1 ℃. Equipped with air purification device and exhaust gas treatment system to prevent cross-contamination and meet environmental standards.

$ 5227.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column, intelligent microcomputer control to achieve automatic operation and online water quality monitoring, effective removal of trace ions.

$ 3430.00

The centrifugal fan with low energy consumption and reasonable air duct design is used to achieve uniform and stable airflow; the average wind speed is 0.25 to 0.45m/s, and the noise is less than or equal to 62dB (A); it is equipped with initial effect and effective Filter to meet the requirements of purification level.

$ 1013.00

Flow velocity 1.5L/min, reverse osmosis (RO) membrane and purification column are used to remove trace ions efficiently, and intelligent microcomputer control realizes automatic operation and online water quality monitoring.

$ 2784.00

The quasi-closed Glass damper prevents external air flow from penetrating, the dual-gear adjustable air volume system maintains the wind speed of 0.3~ 0.6m/s, the 304 stainless steel countertop is resistant to corrosion and easy to clean, and the purification efficiency reaches 100 levels.

$ 741.00

The integrated stainless steel countertop is corrosion resistant and easy to clean, equipped with any positioning sliding door system, the average wind speed is 0.3~ 0.6m/s, the cleanliness level is up to 100, and the pre-Filter quick replacement design is safe and convenient to use.

$ 1248.00

Articles

The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Application of Roll-to-Roll Coating Machine in UV-Curable Coatings
This article introduces the synergistic application of roll-to-roll coating machines and UV curing systems in the production of UV-curable coatings.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
Corrugated Board Impact Resistance - Application of Puncture Strength Tester in Packaging Testing
The impact resistance of corrugated cardboard is crucial for transportation protection, with puncture strength being a key indicator of its ability to withstand dynamic impacts. The puncture strength tester simulates impacts using a pendulum system and measures the energy consumed to penetrate the cardboard, with results expressed in joules or kilojoules per square meter.
Preparation of silver nanowire transparent conductive films by the wire bar coating method
The preparation of silver nanowire transparent conductive films using a coating method is an efficient and scalable production process. This article systematically elaborates on the technology from aspects such as principles, materials, processes, performance characterization, and standards.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.
The versatile electric furnace is still being used as a hot plate, but 90% of people are unaware of these hidden functions.
In addition to basic heating, the universal electric furnace has many practical functions that are often overlooked. It features a built-in temperature control system that allows for programmed automatic heating, making it suitable for experiments requiring precise temperature control.
Don't be fooled by the specs! The 3 key metrics to focus on when purchasing a tensile testing machine.
When purchasing a tensile testing machine, don’t just look at the parameter sheet. Focus on three core indicators: first, the accuracy and range of the force measurement system; second, the accuracy of displacement and deformation measurements; and third, the performance of the control and data acquisition system.
Factors Influencing the Coating Accuracy of Laboratory Film Coaters and Calibration Methods
This article outlines the main factors affecting the coating accuracy of laboratory film applicators, including the mechanical condition of the equipment, process parameter settings, as well as material and environmental conditions. The article points out that coating accuracy directly impacts the reliability of experimental data and requires systematic methods for evaluation and control.
The working principle of laboratory wire rod coaters and methods for controlling coating thickness
The laboratory wire rod coater is a precision instrument used to prepare uniform, thickness-controllable wet film coatings on substrate surfaces. Its core components include a coating rod, a flat coating platform, clamps for securing the substrate, and a mechanical system that drives the coating rod to move at a constant speed.
Comprehensive Guide to Paint Film Thickness Measuring Instruments
This article aims to systematically outline the technical principles, applicable scenarios, and relevant standards of various paint film thickness measurement instruments, providing a reference for professional technicians.
Complete Guide to Methods for Determining the Flexibility of Paint Films
This article systematically outlines the core methods for determining the flexibility of paint films, including the mandrel bending test based on GB/T 1731, the cylindrical mandrel bending method according to GB/T 6742, and the conical mandrel bending method specified in GB/T 11185, providing a detailed explanation of the technical principles of each method.