Box Temperature Test Paper

The box temperature test paper is based on the principle of color change in thermosensitive materials. When the ambient temperature reaches a preset threshold, the coating undergoes an irreversible color change. It is used for monitoring internal temperatures in ovens and sterilization equipment, confirming whether the target temperature has been reached through colorimetric comparison.
Selection
When selecting, match the common temperature range of the equipment, and consider the accuracy error and response time of the test strips. Pay attention to the temperature resistance of the substrate and the compatibility of the adhesive. The color difference during color change should be distinct and easily recognizable. Using a combination of multiple temperature points can cover a wider monitoring range.

Terms

Standards

Instruments

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

Using 3mm thick A3 steel plate and SUS201 stainless steel inner box, the size of each test box is 500 * 500 * 500mm, with pressure relief device and temperature and pressure control, effectively preventing battery explosion and ensuring safe operation.

$ 1535.00

Adopt three-box structure to achieve rapid temperature conversion, conversion time ≤ 10 seconds, temperature control accuracy of +/- 0.5 ℃, equipped with air passage switching system and microcomputer equilibrate temperature control system to ensure test Stability.

$ 24150.00

The three-box structure realizes independent temperature control in the high temperature and low temperature area, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, the air circuit switching Impact mode is adopted, and the microcomputer equilibrating temperature control system is equipped.

$ 20712.00

The three-box structure is used to achieve independent temperature control in the high temperature zone, low temperature zone and test zone, with a temperature conversion time of less than or equal to 10 seconds. It is equipped with rigid polyurethane foam insulation materials and supports 2 or 3 boxes of Impact mode to meet different standard testing requirements.

$ 12757.00

Three-box structure design, temperature conversion time ≤ 10 seconds, temperature recovery time ≤ 5 minutes, equipped with High Accuracy microcomputer control system, can simulate extremely high temperature and extremely low temperature environment for static Impact testing of materials.

$ 22439.00

The three-box heat storage and cold storage structure is adopted to achieve rapid temperature conversion of ≤ 10s, and the temperature recovery time is ≤ 5 minutes. It supports Impact testing at 150 ° C in high temperature zone and -40 ° C in low temperature zone, and has program memory and Linear dispersion recording functions.

$ 17307.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is combined with the forced air circuit switching, the temperature conversion time is less than or equal to 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the impact conditions are independently set in the high temperature and low temperature regions.

$ 19583.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and air passage switching system to achieve fast and stable Thermal Shock testing.

$ 36381.00

With three-box structure design, the temperature conversion time is only 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, and it is equipped with touch graphic operation interface and dual Compressor chill down system to ensure stable and efficient testing.

$ 55261.00

Three-box structure design, temperature conversion time does not exceed 10 seconds, temperature control accuracy of +/- 0.5 ℃, liner size 800 * 850 * 600mm, suitable for material thermal expansion and contraction test, easy to operate.

$ 28490.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.

$ 28684.00

The three-box structure design is adopted, the temperature conversion time does not exceed 10 seconds, the temperature control accuracy is up to +/- 0.5 ℃, the Thermal Shock test is realized through the air circuit switching, and the touch graphic operation interface is equipped to simplify the operation process.

$ 16759.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

Articles

Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.