Automatic calibration without preheating zero adjustment, 1.5 seconds fast measurement, accuracy of 0.1, equipped with 4mm small diaMeter measurement head, support connecting mobile app and computer software to achieve Data storage and report export.
Adopt 4mm small diaMeter design, accuracy of 0.1, 1.5 seconds fast measurement, support Automatic calibration and APP Data storage, equipped with ceramic whiteboard luminance value greater than 90.
Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.
Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.
The ultra-small design is easy to carry, the automatic zero stabilization function does not need to be calibrated, the moisture-proof process adapts to the harsh environment, the Measurement range is 0~ 199.9, the accuracy is 0.1, and the use of a No. 5 battery can work continuously for more than 50 hours.
Using automatic mechanical pressurization and heating technology, the inlay process is completed automatically, the Heating power is 650W, and the mold sleeve specification is 25mm, which is suitable for edge protection of small irregular samples.
The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.
Sample dosage only 2-16ml, viscosity range of 50~ 3300000mPa · s, temperature accuracy +/- 0.1 ℃, support stepless speed and automatic lifting, temperature and viscosity coefficient correction, data storage methods are diverse.
Maximum load 0.5KN, designed for small force test, compact structure, easy operation, ensure test Stability and Repeatability.
With 60 degree Measurement Angles and Φ 5mm small hole measurement area, support USB and Bluetooth data output, can store 254 sets of data, Automatic calibration without manual adjustment.
Using swirl/spin design, light weight and easy to move, can effectively improve the Measurement accuracy and prevent the instrument from falling, suitable for small workpiece measurement scenarios.
Impact energy 2.7mJ, Impact device mass 75g, small damage to the measured surface, does not damage the hardened layer, suitable for measurement of small and thin parts, the minimum thickness of the specimen is 1mm, and the minimum depth of the hardened layer is 0.2mm.
Using imported wire Rod accuracy of 1 μ m, Spreader rate 5~ 200mm/s adjustable, support scraper and wire Rod two Spreader mode, Heating Temperature Uniformity +/- 3 ℃, suitable for a variety of substrate Film thickness treatment.
Spreader accuracy +/- 0.003mm, Spreader thickness range 0.001~ 10mm adjustable, with Vacuum chuck and heating function, support bar and drawdown blade two coating methods to ensure Spreader uniformity and repRoducibility.
Spreader speed 5-200mm/s adjustable, Spreader thickness range of 0.001-10mm, equipped with Vacuum chuck system to ensure the stability of the substrate, Touchscreen control to achieve accurate operation, improve film repRoducibility.