Jacketed Constant Temperature Water Bath

The jacketed constant temperature water bath circulates a constant temperature medium between the inner and outer walls of its double-layer container structure, maintaining the samples in the inner tank at the set temperature. It is used for constant temperature treatment of laboratory samples and control of reaction conditions, providing a stable temperature environment in applications such as coating viscosity testing and ink drying experiments.
Selection
When selecting, focus on the temperature range covering experimental needs, temperature control precision matching sample sensitivity, bath capacity accommodating sample size, material corrosion resistance suiting solvent types, circulation method meeting uniformity requirements, and an operation interface facilitating parameter settings.

Terms

Standards

Instruments

Water-jacketed structure ensures uniform and stable temperature, and can still maintain thermostatic for a long time after power failure; High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.1 ℃, Uniformity +/- 0.2 ℃; with automatic water level alarm and over-temperature protection function.

$ 543.00

Water-jacketed Heating mode ensures Temperature uniformity +/- 0.5 ℃, and can still maintain thermostatic for a long time after power failure. With independent temperature limit alarm system, low water level automatically stops heating to ensure safe and stable operation of the experiment.

$ 572.00

Water-jacketed heating ensures Temperature uniformity, and can still maintain thermostatic for a long time after power failure; with independent temperature limit alarm system, Temperature Fluctuation +/- 0.5 ℃, supports 1~ 9999 minutes timing, to ensure the safe and stable operation of the experiment.

$ 869.00

Water-jacketed heating is used to ensure uniform and stable temperature, and it can still remain thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization, and the Temperature Fluctuation is only +/- 0.3 ° C, with multiple safety alarm functions.

$ 638.00

Water-jacketed Heating mode to ensure Temperature uniformity, continuous thermostatic after power failure. With independent temperature limit alarm system, Temperature Fluctuation +/- 0.5 ℃, support 1~ 9999 minutes timing, to ensure the safe and stable operation of the experiment.

$ 1111.00

The water-jacketed structure has accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, and can still maintain thermostatic for a long time after power failure. The microcomputer PID controller has sound and light alarm function to ensure the safety and stability of the experiment.

$ 948.00

Water-jacketed heating method, Temperature Uniformity +/- 1 ℃, can still maintain thermostatic for a long time after power failure. The diagonal air duct structure in the box ensures uniform temperature, the mirror stainless steel liner is easy to clean, and the shelf spacing is adjustable for easy use.

$ 574.00

The water-jacketed structure has accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, and can still maintain thermostatic for a long time after power failure. The microcomputer PID controller has an automatic alarm function, and the studio is made of mirror stainless steel.

$ 462.00

Water-jacketed structure with accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, can still maintain thermostatic for a long time after power failure, using mirror stainless steel studio and semi-circular design for easy cleaning.

$ 725.00

Water-jacketed heating ensures Temperature uniformity, and can continue to maintain thermostatic after power failure; with independent temperature limit alarm system, Temperature Fluctuation +/- 0.5 ℃, providing a stable foster environment.

$ 649.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Adopt diagonal air duct structure to ensure Temperature Uniformity +/- 1 ℃, Water-Jacketed heating can still maintain thermostatic after power failure, equipped with PID control and independent temperature limit alarm system to ensure the safe and stable operation of the experiment.

$ 1114.00

Using Water-Jacketed heating technology, it can still maintain thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization; the temperature control accuracy is +/- 0.3 ° C, the uniformity is +/- 0.5 ° C; it has multiple safety alarm functions.

$ 720.00

Water-Jacketed heating is used to ensure uniform temperature and maintain thermostatic after power failure. With over-temperature protection, Sensor fault detection and water level monitoring functions, Temperature Fluctuation is controlled within +/- 0.5 ° C.

$ 699.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00