Single-paraMeter total nitrogen water quality Detector

The single-parameter total nitrogen water quality detector converts nitrogen compounds in water samples into nitrates through alkaline potassium persulfate digestion, followed by concentration determination via UV spectrophotometry. It is used to monitor nitrogen levels in water bodies and is suitable for daily testing in scenarios such as wastewater treatment plant discharge outlets and aquaculture water bodies.
Selection
When selecting, focus on ensuring that the measurement range covers the actual water concentration, the digestion temperature and time comply with standard methods, and the instrument has an automatic calibration function. Consider the reagent storage conditions and the instrument's protection rating, and verify the local environmental protection department's requirements for the acceptance of test data.

Terms

Instruments

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.

$ 2505.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.

$ 767.00

Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.

$ 622.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Can simultaneously measure 10 water quality indicators, IP67 waterproof design to adapt to harsh environments, built-in 45000 sets of data storage capacity, automatic identification of calibrating points to ensure Measurement accuracy.

$ 2247.00

Measurement range 0.000~ 1.000mg/L, including 100mL molybdate solution, 25 packs of ascorbic acid powder and 25 packs of potassium persulfate powder, suitable for water quality total phosphorus detection.

$ 164.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Integrate 8 water quality paraMeter measurement functions, support automatic temperature compensation and calibrated reminders, equipped with 500 sets of data storage capacity, and adopt multi-mode power supply scheme to ensure long-term outdoor use.

$ 909.00

Digestion instrument and measuring instrument separation design to ensure measurement accuracy, using PID automatic temperature control technology, can save 30 standard Linear dispersion and 199 sets of measurement data, support room temperature to 180 ℃ wide range of temperature control.

$ 1742.00

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

It can simultaneously detect 9 paraMeters such as residual chlorine, chlorine dioxide, ammonia nitrogen, etc., with a resolution of 0.001mg/L. It adopts high-intensity long-life Illuminant and micro-processing technology to ensure long-term stable operation.

$ 877.00

Measurement range 0~ 500 ppm, accuracy +/- 3 ppm, support for CAL CheckTM Adjustment, suitable for a variety of water quality testing scenarios.

$ 215.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.