Carbon Monoxide Online Monitor

The carbon monoxide online monitor detects CO concentration in the air using an electrochemical sensor, converting chemical signals into electrical signals for output. It is used for real-time monitoring in enclosed environments such as printing workshops and plastic processing facilities to prevent personnel poisoning and equipment corrosion.
Selection
Select a model that confirms the measurement range covers 0-1000 ppm, with a resolution of 1 ppm. Pay attention to sensor lifespan and calibration intervals, ensuring the explosion-proof rating matches the on-site environment. Prioritize models equipped with 4-20mA and RS485 outputs for easy integration into the existing control system.

Terms

Standards

Instruments

Using electrochemistry principle to detect carbon monoxide, with a range of 0~ 1000ppm, with four Alarm modes and wireless data transmission functions, support temperature compensation algorithm and a variety of usage methods.

$ 254.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 296.00

Electrochemical sensor to achieve 0-1500ppm range detection, Response Time less than 10 seconds, with Intrinsic Safety (IS) design and a variety of signal output, support remote monitoring and automatic Zero tracking, suitable for harsh industrial environments.

$ 296.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with explosion-proof certification and a variety of output interfaces, support remote monitoring and automatic zero point calibrating.

$ 812.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with automatic Zero tracking and temperature compensation function, explosion-proof design for dangerous places, support a variety of signal output interfaces.

$ 682.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with intrinsically safe circuit design and explosion-proof certification, support for multiple output interfaces and automatic Zero tracking, suitable for harsh industrial environments.

$ 682.00

Imported Electrochemical sensor, Response Time less than 10 seconds, Measurement accuracy +/- 2% F.S., with intrinsically safe circuit design and explosion-proof certification, support multiple output interfaces and automatic Zero tracking.

$ 812.00

Supports simultaneous detection of 4 gases, Integrated Temperature Humidity Detection, Compatible with Pumping and Diffusion Sampling method, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Operating temperature range -40~ 55 ℃.

$ 716.00

Electrochemical sensor detects 0-1000ppm carbon monoxide, Response Time is less than 60 seconds, through LCD display and buzzer grading alarm, portable design weighs only 115 grams.

$ 170.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch IPS high definition screen, support 1-6 Sensor expansion, with 4-20mA, RS485 and other signal output, Protection Rating IP65, Response Time ≤ 20 seconds.

$ 280.00

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with explosion-proof design and a variety of output interfaces, support remote monitoring and automatic Zero tracking, adapt to harsh industrial environment.

$ 682.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds; with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions, strong anti-interference ability.

$ 361.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions, strong anti-interference ability.

$ 682.00

Electrochemical sensor, detection range 0-40000ppm, Response Time less than 10 seconds, with explosion-proof certification and a variety of output interfaces, suitable for harsh environments, automatic zero tracking to prevent drift.

$ 682.00

Articles

Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.