Methane Viscosity Measuring Instrument

The methane viscometer calculates viscosity by measuring the resistance of methane gas as it flows through a capillary tube. It is used to detect gas flow characteristics and is applied in natural gas quality control and efficiency evaluation of distribution pipelines.
Selection
When selecting, consider that the measurement range covers actual methane viscosity values, the accuracy meets industry standards, it is compatible with existing gas source interfaces, the operation interface is simple, and the maintenance cycle and cost align with the laboratory's regular budget.

Terms

Standards

Instruments

Using 6mm filter diaMeter, viscosity measurement range 188-684cSt, flow time 30-100 seconds, in line with international standards design, suitable for rapid viscosity evaluation of newtonian fluids, aluminum alloy structure to ensure durability.

$ 432.00

Support simultaneous detection of 4 kinds of gases, integrated temperature and Humidity detection, Response Time T90 ≤ national standard, Protection Rating IP66, with Internet of Things remote monitoring and a variety of Installation methods.

$ 277.00

Supports simultaneous detection of 4 gases, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Pump sampling ensures stable airflow, fast detection Response; can store 100,000 data, support different interval recording; with double alarm function, battery life of 10-60 hours, adapt to -40~ 55 ℃ working environment.

$ 254.00

Maximum support 4 kinds of gas simultaneous detection, integrated temperature and humidity monitoring and physical + software double compensation, using dual temperature and humidity design and 10 Meters visual distance high definition color screen, Protection Rating up to IP66 and operation temperature range -40~ 55 ℃.

$ 393.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Using high-quality aluminum alloy and stainless steel material, aperture 4.12mm, viscosity measurement range of 70~ 370cSt, flow time of 20~ 105 seconds, through the flow time to evaluate the liquid viscosity characteristics.

$ 130.00

Support simultaneous detection of 4 gases, integrated temperature and Humidity detection, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 301.00

Designed for easy immersion measurement with one hand operation, the 8mm filter diaMeter covers a specific viscosity range, and the aluminum alloy and stainless steel construction ensures durability and accurate flow time determination.

$ 388.00

Using aluminum alloy material, filter diaMeter 4mm, viscosity measurement range 34-135cSt, in line with international standards design, hand-held immersion operation is simple, suitable for laboratory accurate measurement.

$ 432.00

ABS + PC shell is sturdy and durable, equipped with 2.0 inch 320 * 240 resolution display screen, supports methane, O2, H2S, CO four Gas detection, Response Time is the fastest 20 seconds, battery life is 8 hours, with sound and light vibration triple Alarm mode.

$ 344.00

Using 10L Glass Bathtub, small size and less medium consumption, temperature control accuracy of +/- 0.05 ℃, automatic accurate timing and viscosity calculation, support 4 holes at the same time experiment, easy and reliable operation.

$ 1910.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.