Underwater Metal Thickness Gauge

The underwater metal thickness gauge operates based on the principle of ultrasonic reflection on metal surfaces. The probe emits sound waves and receives the echoes, calculating the thickness based on the propagation time. It is used for inspecting underwater structures such as ships and offshore platforms, allowing measurements without the need to remove attached organisms.

Instruments

The 90 ° right angle Probe design is suitable for low headroom area measurement, the fully waterproof structure supports underwater operation, the Measurement accuracy is +/- (0.05 mils + 1%), and the stainless steel sealing Probe ensures durability.

$ 787.00

Measurement accuracy of +/- (0.05 mils + 1%) with 90 ° right angle design for low headroom area measurement, fully waterproof structure for underwater operation, stainless steel sealing Probe for durability.

$ 895.00

Measurement range 0~ 625μm, accuracy +/- 1%, waterproof sealing structure suitable for underwater measurement, constant pressure Probe to ensure measurement Stability.

$ 1072.00

Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.

$ 320.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement range 0~ 1500 microns, error +/- 1%, support magnetic Induction principle, IP65 Protection Rating and 250 reading storage, suitable for ferrous metal substrate nonmagnetic coating environment.

$ 890.00

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Detachable built-in Probe design, support one-handed operation, Measurement range 0~ 13mm, accuracy +/- 3%, suitable for Coating thickness detection of different metal substrates.

$ 932.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250 microns, equipped with thermal printer can print test data in real time, suitable for a variety of nonmagnetic metal substrate insulation coating thickness detection.

$ 219.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250 microns, minimum substrate 0.3mm, with continuous testing, Data storage and a variety of calibrating modes, easy operation and high accuracy.

$ 364.00

The eddy Current principle is used for measurement of nonconductive coatings on non-ferrous metal substrates, with a thickness range of 0~ 625μm and an error of +/- 3%. It has IP65 Protection Rating and fast measurement capabilities of more than 60 readings per minute.

$ 1338.00

Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.

$ 323.00

Measurement range 0.65-400 mm, the highest accuracy is +/- 0.04mm, supports four measurement modes, Data storage 3000 groups, high-speed measurement up to 10 times/second, suitable for a variety of metal materials.

$ 835.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.