Combustible Gas Detection Probe

Flammable gas detectors measure the concentration of combustible gases in the air using catalytic combustion or infrared absorption principles. When gas contacts the sensor, it generates an electrical signal change that triggers an alarm. These devices are used for leak detection and safety protection in places such as chemical plants and gas stations.
Selection
When selecting, consider matching the sensor type to the types of gases being detected. Determine the explosion-proof rating and protection standards based on the usage environment. Refer to response time and detection range to meet on-site requirements. Perform regular calibration and maintenance to ensure long-term stability.

Terms

Standards

Instruments

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

Supports simultaneous detection of four gases and temperature Humidity, adopts dual temperature Humidity compensation design, has zero point automatic correction function, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 301.00

Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.

$ 99.00

Can simultaneously detect four gases, Electrochemical sensor, Response Time instant, alarm sound up to 80 decibels, operation temperature range -10~ 50 ℃, portable design weighs only 360 grams.

$ 241.00

Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity compensation, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 693.00

Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and infrared remote control operation, through a number of international safety certifications.

$ 190.00

It adopts flameproof structure design, supports 4-20mA, RS485 and switch output, Response Time ≤ 30 seconds, Detection error ≤ +/- 3% F.S. It can be operated by remote control without opening the lid, with sound and light alarm function, suitable for dangerous environment gas monitoring.

$ 254.00

Catalytic combustion Sensor, adjustable detection accuracy, temperature compensation and automatic zero correction function, support 4~ 20mA output and RS485 digital output, suitable for hazardous areas.

$ 143.00

Using infrared NDIR detection principle, range 0-1000ppm, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output options, support remote data transmission and customized range.

$ 848.00

Using infrared NDIR detection principle, range 0-5% Vol, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote monitoring capability.

$ 332.00

Using catalytic combustion principle to detect 0-100% LEL range, Response Time ≤ 30 seconds, with flameproof structure and multi-signal output, support remote monitoring and customized Sensor.

$ 202.00

Maximum support for simultaneous detection of 4 gases, integrated temperature and Humidity detection, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods and harsh environments.

$ 277.00

Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation functions, support 4~ 20mA output and infrared remote control debugging, suitable for dangerous areas 1 and 2 zones.

$ 143.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Articles

Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Principles and Selection of Film Thickness Measurement Instruments
This article introduces the principles and selection methods of thin film thickness measurement instruments. The measurement principles are mainly divided into contact and non-contact methods, which calculate thickness by detecting the differences in the thin film's response to physical signals.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.