Temperature measurement point sticker

The temperature measurement point sticker is a self-adhesive temperature indicator material that changes color within a specific temperature range based on the thermochromic principle. It is used to monitor the surface temperature of objects and is commonly applied in scenarios such as equipment overheating warnings and process temperature verification.
Selection
When selecting, consider the measurement temperature range and accuracy requirements, ensuring compatibility with the surface material and curvature of the object being measured. Pay attention to the size of the sticker and its environmental adaptability, such as resistance to moisture and chemical corrosion. Check the product certifications and validity period to ensure reliability.

Terms

Standards

Instruments

Irreversible discoloration design, the temperature window from white to red is clearly recognizable, with oil-proof and waterproof protective film, the back sticker is easy to paste, can be stored for 2-3 years, each 120 pieces size 12x30mm.

$ 150.00

Single point temperature monitoring, permanent discoloration irreversible after overheating, specification 2.5x4 cm, with anti-fouling protective film, indoor service life of 3 years, outdoor 2 years.

$ 89.00

Single point temperature measurement design, temperature point 70 ℃, irreversible discoloration characteristics, anti-fouling protective film design, specification 2.5x4 cm, service life indoor 3 years.

$ 87.00

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Irreversible discoloration records the temperature. When the temperature is exceeded, the window is obviously visible from white to red. It has an oil-proof and waterproof protective film and a adhesive backing for easy pasting. Each sheet is 120 pieces, and the shelf life is 2-3 years.

$ 150.00

With 5 temperature monitoring points, Temperature range 77 ° C to 99 ° C, irreversible discoloration record, oil and water resistance, BS EN ISO 9001 compliant, with a sticker on the back for easy installation.

$ 92.00

Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation to ensure measurement Stability and accuracy.

$ 696.00

Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.

$ 696.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.

$ 696.00

Quickly calculate the dew point through the wet-bulb temperature Measurement principle, support direct reading of relative humidity, integrated temperature unit conversion function, easy operation without complicated settings.

$ 240.00

Temperature range of 50~ 120 ℃, irreversible discoloration, over-temperature grid window from white to red, clear contrast, suitable for indoor and outdoor equipment temperature display.

$ 140.00

Measurement accuracy up to 0.01pH with 2 point button calibrating and automatic temperature compensation, 50 data storage and USB Communication interface to ensure High Accuracy measurement.

$ 323.00

With 5 point button Adjustment, Measurement accuracy of 1% F. S, Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, equipped with USB interface for data transmission.

$ 696.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic temperature compensation, 500 data storage and USB Communication interface support, ensuring measurement accuracy and data traceability.

$ 696.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Vicat softening point tester measures the heat deflection temperature of special engineering plastics.
The Vicat softening point tester measures the temperature at which a needle penetrates a plastic sample to a specified depth by heating and applying a load, thereby evaluating the heat deflection temperature of special engineering plastics.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.