Water Quality Automatic Monitor

Water quality automatic monitors continuously detect parameters such as pH, turbidity, and dissolved oxygen in water through sensors, converting chemical signals into electrical signals transmitted to the control unit. They are used for real-time water quality monitoring in rivers and wastewater treatment plants, replacing manual sampling.
Selection
When selecting, consider the matching requirements for monitoring parameters, compare electrode lifespan and maintenance cycles, check lightning protection and IP ratings, confirm data interface compatibility with existing systems, and evaluate reagent consumption and operational costs.

Terms

Instruments

Equipped with a 5.1-inch LCD screen to monitor water quality in real time, support three-way water quality and temperature display, automatically cycle to prolong the life of consumables, set the use time of consumables and remind, and one-click disinfection function to reduce bacterial contamination.

$ 1498.00

The 5.1-inch LCD screen displays three-way water quality and temperature in real time, with regular automatic circulation function to maintain water quality stability, water resistivity > 18.2MΩ · cm, support for consumable life setting and remote monitoring.

$ 1629.00

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

With 40L/H water pRoduction capacity and 18.2MΩ · cm resistivity, 5.1-inch large screen real-time display of water quality, automatic circulation and disinfection system to extend the life of consumables, support regular quantitative water intake, all-plastic shell rust-proof and durable.

$ 2205.00

12 water quality paraMeters can be measured simultaneously, with IP67 waterproof rating and 45,000 data storage capacity, support automatic temperature compensation and fast calibrating, with backlit graphic display and intuitive Operating interface.

$ 2949.00

Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.

$ 2363.00

With 18.2 MΩ · cm high resistivity effluent, micro particulate matter (PM) less than 1/ml, support automatic circulation and consumable life management, 5.1 inch large screen real-time display of water quality paraMeters, optional disinfection function.

$ 2468.00

Can simultaneously measure 10 water quality indicators, including pH, ORP, conductivity, etc., with IP67 waterproof and automatic temperature compensation function, data storage capacity of 45,000, adapt to harsh environment measurement needs.

$ 3373.00

The resistivity of the pRoduced water is greater than 18.2MΩ · cm, the water pRoduction capacity is up to 100L/H, and it is equipped with a 5.1-inch LCD screen to display water quality and temperature in real time. It supports automatic circulation and disinfection functions, effectively prolonging the life of consumables.

$ 3097.00

Equipped with 80L/H water pRoduction capacity and 18MΩ · cm resistivity effluent, 7-inch color touchscreen displays water quality and temperature in real time, supports automatic circulation and consumable reminders, is compatible with a variety of water storage methods, and has built-in disinfection function.

$ 4932.00

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

Can simultaneously measure 7 water quality indicators, IP67 waterproof design, 45000 data storage capacity, support 1 second to 3 hours custom storage interval, with automatic temperature compensation and GLP management function.

$ 2615.00

16 water quality paraMeters can be measured simultaneously, equipped with IP67/IP68 waterproof rating, support automatic temperature compensation and 44,000 Data storage, Measurement accuracy of +/- 0.02pH, intuitive and convenient operation.

$ 7264.00

It can simultaneously measure 10 water quality paraMeters, equipped with IP67 waterproof body and IP68 ElectRode, data storage capacity up to 45000 groups, support automatic temperature compensation and range identification, to ensure measurement accuracy in harsh environments.

$ 2904.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Articles

Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.