Aluminum Melt Stirrer

The aluminum water stirrer generates vortices through rotating blades to ensure uniform composition and temperature of the aluminum liquid. It is used in smelting furnaces to reduce oxide inclusions and improve casting quality. It is applied in scenarios such as aluminum alloy production and recycled aluminum recovery.
Selection
Match the stirrer power according to the furnace capacity, taking into account the blade's resistance to high-temperature corrosion. Electromagnetic stirring is suitable for applications with high cleanliness requirements, while mechanical stirring is better suited for complex alloy conditions. Focus on energy consumption and maintenance costs, and ensure the reliability of the sealing system.

Terms

Instruments

The use of brushless DC motor to achieve stepless speed regulation of 100~ 1500rpm, temperature control accuracy of +/- 1 ℃, aluminum alloy die-casting shell to ensure durability, energy saving under the same conditions more than 50%.

$ 307.00

Temperature control accuracy of +/- 0.5 ℃, equipped with eight standard test force, can accurately determine the melt flow performance of polymers at high temperatures, to meet a variety of material testing needs.

$ 977.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Adopting MCU to adjust power and temperature control mode, temperature control accuracy +/- 0.5 ℃, with eight standard test force, can meet the needs of different material testing, suitable for melt flow performance measurement at high temperature.

$ 945.00

Microcrystalline Pottery and porcelain plate surface corrosion resistance and easy to clean, aluminum alloy shell integrated molding, speed range 0-1250rpm stepless speed, Max.stirring Capacity 3L, ND servo motor drive output power 9W.

$ 251.00

The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.

$ 554.00

Aluminum die-casting ceramic coating working plate is resistant to abrasion and corrosion, the highest temperature is 350 ° C, the temperature control accuracy is +/- 0.2 ° C, the DC brushless motor runs smoothly with low noise, and the double heating control circuit ensures temperature stability.

$ 493.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 2000rpm, aluminum alloy heating plate Power 600W rises rapidly, temperature control accuracy +/- 1 ℃, heating plate temperature can be directly set and with safety restrictions.

$ 273.00

Measurement range 0.000~ 0.3mg/L, can be 100 measurements, supporting special instruments to achieve fast and accurate water quality aluminum ion detection, including a variety of Reagent solutions.

$ 164.00

It can measure the minimum inner diaMeter of 6mm aluminum tube and 8mm thickness profile, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, support Hardness value multi-standard conversion.

$ 1219.00

Enclosed aluminum silicate Furnace and nickel-chromium-aluminum alloy heating wire are used to reduce volatile gas corrosion; three-sided heating method combined with PID control, Temperature Fluctuation +/- 5%, accurate and stable temperature control.

$ 1138.00

Maximum stirring capacity 3 liters, stirring speed 200~ 1800rpm stepless speed regulation, Heating power 450W, Temperature range RT + 5~ 320 ℃, using aluminum alloy die-casting shell, high temperature corrosion resistance easy to clean.

$ 311.00

The activated aluminum oxide ball is used as the adsorption medium, which can adsorption water vapor and chemical corrosion harmful gases, and the oil blocking rate is more than 99%.

$ 146.00

Three-sided heating method with aluminum silicate Furnace, high thermal efficiency and uniform temperature. PID control combined with K-type Thermocouple, temperature control accuracy +/- 5%, support 0~ 9999 minutes timing and phased heating.

$ 606.00

With low temperature OLED display, it can still work normally in -40 ℃ environment; equipped with iron-aluminum dual-use Probe, automatically identify the substrate and convert the mode; Measurement speed is as fast as 0.5 seconds, error range +/- 3%.

$ 175.00