Coating Crosshatch Blade

The paint grid cutter is used to assess the adhesion of coatings by cutting a grid pattern on the surface with blades and observing the degree of peeling. It evaluates the bonding strength between the coating and the substrate, and is applied in coating quality inspection and process validation.
Selection
When selecting, consider the hardness of the substrate matching the blade spacing, the coating thickness corresponding to the cutting depth, and the comfort of the handle grip. The stainless steel material ensures durability, and the grid template specifications must meet the requirements of the testing standards.
Tooth spacing
Number of teeth
Test substrate
Measured film thickness
Number of blades
Applicable standard
Miscellaneous

Terms

Standards

Instruments

Blade Coating method, coating speed 1~ 500mm/s stepless speed regulation, wire speed accuracy +/- 1%, equipped with Vacuum chuck and heating function, clamshell drawdown blade design for easy cleaning, support application length and speed free adjustment.

$ 5883.00

With bar and drawdown blade two coating methods, coating speed 1~ 300mm/s stepless speed regulation, clamshell drawdown blade design for easy cleaning, bar accuracy of +/- 0.001mm, Blade Coating thickness range of 0.1~ 10mm, effective coating area 1500 * 300mm.

$ 7335.00

Adopt clamshell type Blade Coating head design, easy to clean; coating speed 1~ 300mm/s stepless speed regulation, Spreader accuracy up to +/- 0.003mm, to meet the laboratory High Accuracy film needs.

$ 2978.00

With bar and drawdown blade two coating methods, Spreader thickness range 0~ 10mm, coating speed 5~ 200mm/s, support stepless speed and automatic feeding customization function.

$ 9755.00

With meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, support Vacuum chuck and fixture fixing, coating table size 1440 * 1030mm, clamshell design is easy to clean.

$ 19438.00

Measurement range of 10-1000 μm with dual blade design, LED lighting Microscope and swirl/spin system to accurately assess substrate and coating defects, reducing computational requirements.

$ 299.00

Adjustable Blade Coating device to achieve 0.005-3mm thickness control, equipped with 200 ℃ heating roller and 1 Meter drying tunnel, support 1-10m/min continuous coating speed, with automatic correction function to ensure material alignment.

$ 19438.00

Using Blade Coating method, Spreader accuracy of +/- 10μm, Spreader thickness range of 0~ 5000μm, support stepless speed control and Touchscreen operation, effectively improve film conformity and experimental efficiency.

$ 1606.00

Adopt imported accessories to ensure Stability, Blade Coating accuracy up to +/- 0.003mm, coating speed 5~ 200mm/s adjustable, effective coating area 400 * 400mm, improve film repRoducibility by controlling speed and pressure.

$ 2655.00

Adopt adjustable Blade Coating, high film thickness control accuracy, application length and speed can be adjusted freely, equipped with heat-resistant and scratch-resistant tempered Glass countertop, easy to clean and easy to operate.

$ 6205.00

Adopt bar and Drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, bar accuracy +/- 0.001mm, equipped with clamshell Drawdown blade head for easy cleaning, Glass countertop heat resistance 600 ℃.

$ 5560.00

Adopt bar and drawdown blade double coating method, coating speed 1~ 300mm/s stepless speed regulation, Blade Coating Film thickness 0.1~ 10mm, equipped with Vacuum chuck and heating function, film uniform accuracy is high.

$ 14597.00

Adopt adjustable Blade Coating, Spreader thickness range 0~ 10mm adjustable, coating speed 5~ 200mm/s, with Platen Heating and Vacuum chuck function, improve film repRoducibility and operation convenience.

$ 11046.00

With bar and drawdown blade dual Spreader function, coating speed 1-300mm/s stepless speed regulation, Spreader accuracy of +/- 0.003mm, clamshell drawdown blade design for easy cleaning, servo motor drive to ensure smooth operation.

$ 4914.00

Adopt bar and Drawdown blade double coating method, coating speed 5~ 180mm/s adjustable, Spreader thickness range 0~ 10mm, equipped with clamshell Drawdown blade head and Touchscreen control, easy to operate and easy to clean.

$ 9755.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.