Using platinum temperature sensor and digital Optical inspection technology, temperature control accuracy 0.1 ℃, can process 2 samples at the same time, with video recording playback function, support 0.1-10 ℃/min heating rate.
The black background counting cell is used with annular fluorescent lamp side-shot illumination, and the colony contrast ratio is clear; the counter capacity is 0-999, and the inclined design of the cell surface is easy to observe, which can reduce the labor intensity of the experimenters.
With an impact speed of 2.9m/s or 3.8m/s, it supports a variety of sample sizes, uses semi-automatic control to improve operation efficiency, and can display information in real time and print out the results.
The CMOS integrated circuit is used to ensure stable counting, and the 7W energy-saving ring lamp side-shot illumination makes the colony contrast clear. The counter capacity is 0-999 to meet the needs of conventional detection. The probe pen marking function is avoided, and the repeability count is performed.
Using platinum plate or ring method measurement, the range is 0~ 400mN/m, the minimum resolution is 0.1mN/m, the manual lifting and lowering points are fast and micro-adjusted, and the output data of RS232C interface is supported.
The XY axis displacement platform and the lifting measurement platform are used to facilitate accurate fine-tuning and measurement of small samples such as O-rings; the servo system imported from Japan ensures accurate positioning, and the built-in micro printer supports data output.
Measuring methods of platinum plate and platinum ring are supported, with resolution up to 0.01mN/m, equipped with fast fine-tuning manual lifting platform, and can display data in real time through RS232 interface.
Force range 5~ 3000N, accuracy +/- 1%, support ring pressure, side pressure, gluing, flat pressure and other 6 tests, equipped with 5.0 Touchscreen and thermal printer, suitable for paper Cardboard strength detection.
Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.
Measurement range 0~ 14pH, Operating temperature 0~ 80 ℃. High strength conical sensitive membrane can pierce semi-solid sample.
Thrust sampling mode, cutting edge pressure sample 25mmx100mm and gluing sample 25mmx80mm, sampling thickness range of 18mm, suitable for Corrugated Board and carton mass detection.
The pressure-sensitive element is used for automatic counting, the diaMeter of the culture dish supports ≤ Φ 90 mm, and it is equipped with dark deep background and annular fluorescent side-shot lighting. The colony contrast is clear, and the counting is fast and reliable.
Suitable for solid-state semi-solid piercing measurement, using high-performance ceramic core liquid junction and long-life reference structure, Measurement range 0-14pH, Temperature range 0-60 ℃.
Equipped with A/B/C/E four kinds of corrugated pins, the diaMeter of the pins is Φ 2-3mm, the straight line is arranged without bending, and the unit length Corrugated Board gluing line can be separated to meet the testing needs of different sizes of paper pRoducts.
CMOS integrated circuit design, equipped with energy-saving ring fluorescent lamp side lighting, the counter capacity of 0~ 999, can automatically count and chromadizing mark colonies, reduce the labor intensity of experimenters.