Constant Temperature and Humidity Test Chamber for Paint Film

The constant temperature and humidity test chamber for paint films maintains a set temperature and humidity environment in an enclosed space through its temperature control system and humidification device. It is used to simulate the weather resistance performance of paint films under different climatic conditions, detecting changes such as blistering, cracking, and discoloration of coatings. It is widely applied in product quality verification across industries such as coatings, automotive, and furniture.
Selection
When selecting, consider the temperature and humidity range and control accuracy required by the testing standards. The workspace dimensions must match the sample specifications. Pay attention to the equipment's temperature uniformity and fluctuation indicators, and the humidity system should preferably use steam humidification. Ensure it has safety protection and data logging functions, choose a compressor type suitable for long-term operation, and confirm the availability of convenient after-sales maintenance.

Terms

Standards

Instruments

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.

$ 1414.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.

$ 1627.00

Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.

$ 4122.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.

$ 3630.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.

$ 4663.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Temperature resolution up to 0.1 ℃, Humidity Control Range 60~ 85% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure experimental safety.

$ 2347.00

Using imported Sensor and TMHM equilibrating Conditioning method, temperature control accuracy of +/- 0.5 ℃, humidity control accuracy of +/- 3% RH, with independent temperature limit alarm system to ensure experimental safety.

$ 3531.00

Fluorine-free design, Temperature range -40~ 85 ℃, Humidity control 45~ 95% RH, mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safe operation.

$ 4843.00

Articles

Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Cone Mandrel Bend Tester evaluates the flexibility of coatings under small-diameter bending.
The paint film conical bending tester simulates a gradually varying radius of curvature using a conical shaft to test the flexibility of coatings under small-diameter bending.
Coating Cylindrical Bending Tester for Determining the Resistance of Paint Films to Cylindrical Bending Cracking
This article introduces how the coating cylindrical bending tester measures the resistance of paint films to bending and cracking.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Selection of impact head diameter and drop hammer mass combination for paint film impact tester
When selecting the impactor diameter and drop hammer mass for a paint film impact tester, the key is to balance the impact energy and pressure.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Cylindrical Mandrel Bending Tester for Detecting Flexibility of Coatings
This article introduces how the cylindrical shaft bending tester detects the flexibility of paints. Flexibility refers to the ability of the paint film to resist cracking when the substrate is bent.
Comparison of the Three Principles of Paint Film Adhesion Testers
There are primarily three principles for paint film adhesion testers, and selection should be comprehensively considered based on the coating characteristics, substrate type, and testing purpose.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Use of pendulum hardness tester for paint film curing degree assessment in the laboratory.
The pendulum hardness tester evaluates the hardness of a paint film by measuring the decay time of a pendulum swinging on the surface of the film, where a longer time indicates a harder film and a higher degree of curing.