Laboratory Testing Oven

Laboratory testing ovens heat air through electric heating elements, using temperature sensors and controllers to maintain the set temperature, allowing samples to complete moisture evaporation, curing, or aging tests under constant temperature. They are used in industry quality testing processes such as determining the drying time of coatings, testing the thermal stability of plastics, and analyzing the moisture content of paper.
Selection
Determine the temperature range and uniformity requirements based on sample characteristics; for routine testing, select an accuracy of ±2℃. Choose the internal cavity size according to the sample volume, leaving 20% of space. Consider the corrosion resistance of the stainless steel inner chamber. When programmable temperature control is required, select a model with multi-segment programming. Ensure that overheat protection and grounding safety devices are complete.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Using dip coating process with double roll extrusion residual material, Spreader thickness adjustable, mechanical speed 0.1-1 m/min, Oven temperature 50-150 ℃ +/- 3 ℃, suitable for a variety of Coating Spreader.

$ 21051.00

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

Support 0-3000um Coating thickness adjustment, travel speed 0-5m/min, Oven temperature 40-150 ℃; Modular head can switch extrusion, Drawdown blade and other Spreader functions, integrated tension closed-loop control and infrared drying options.

$ 9433.00

Using roll-to-roll continuous solution pool mode, the width of the substrate is 200mm, and it is dried by 130 ° C hot air Oven; the solution pool can be lifted and heated, and PLC control ensures stable operation, which is suitable for a variety of substrate processing.

$ 48484.00

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Adopt double roll extrusion method to achieve 0.3-10 mm Spreader Film thickness, accuracy of +/- 0.05mm; Equipped with hot air circulation Oven, Temperature range room temperature to 200 ℃ +/- 3 ℃; Tension controller automatically controls the unwinding process to ensure the uniformity of Spreader.

$ 10562.00

Volume 80L, Input Power 850W, Microcomputer P.I.D temperature controller and hot air circulation system to ensure Temperature Uniformity +/- 3%, with over-temperature protection and timing function.

$ 417.00

Large LCD screen, Menu Operating interface, Temperature Fluctuation +/- 1 ℃, Mirror stainless steel liner for easy cleaning, Thickened box design low surface temperature, Thermal Power reduced by more than 25%.

$ 803.00

Spreader thickness range of 10-250μm, Dry-Film accuracy of +/- 3 microns, equipped with automatic constant tension control and four Oven section thermostatic, ensure uniform and stable Spreader, Oven with waste heat recovery system energy saving about 30%.

$ 48484.00

Ceramic fiber material, Temperature range RT + 20~ 400 ℃, liner size 450 × 450 × 450mm, with multi-stage programmable control, independent temperature limit alarm and fast and stable temperature control function, easy to clean and automatic operation.

$ 2052.00

The mirror stainless steel liner is easy to clean, Temperature resolution up to 0.1 ℃, supports multi-stage programmable control, can preset 7-stage 63-step program, and has an independent temperature limit alarm system to ensure safe operation.

$ 1222.00

32 infrared halogen heaters, temperature range RT + 5~ 350 ℃, can be set parabolic layer or rising slope, the maximum test plate size 570mm, support the intRoduction layer Linear dispersion simulation pRoduction process.

$ 108363.00

Using a roll-to-roll continuous solution cell process, the substrate is crystallized or attached under specific conditions. Equipped with a 130 ° C hot air Oven drying system, the effective application width is 180mm, and the mechanical speed range is 0.1-300 mm/min. The solution cell has a lifting function and a separate heating design to ensure process Stability and operation safety.

$ 48484.00

Temperature range 10~ 200 ℃, resolution of 0.1 ℃, hot air circulation system to improve Temperature uniformity, mirror stainless steel liner durable and easy to clean, support timing and over temperature protection function.

$ 493.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Insulation resistance tester measures rubber sealing gaskets.
This article introduces the method of using an insulation resistance tester to inspect rubber sealing gaskets.
Dart impact tester measures the toughness of packaging film.
The dart impact test evaluates the material's resistance to damage under dynamic impact, i.e., its toughness, by allowing a dart to fall freely and strike the packaging film. During the test, different impact energies are simulated by adjusting the weight of the dart or the drop height, and sensors are used to detect whether the film ruptures.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.