Ultra-low temperature cooling liquid circulation pump

The ultra-low temperature coolant circulation pump utilizes a compressor refrigerant circulation system to cool the coolant to below -40℃ and continuously pump it. It is used for constant-temperature cooling of laboratory equipment such as reaction vessels and rotary evaporators to prevent sample volatilization or degradation.
Selection
When selecting, focus on the minimum temperature and temperature control accuracy, match the equipment interface size, determine the pump flow and head parameters based on the heat dissipation load, consider corrosion-resistant materials and safety protection functions, and choose an appropriate model size based on the laboratory space.

Terms

Standards

Instruments

Adopt ultra-low power consumption single chip standby for more than 6 months, imported high luminance Illuminant to ensure repeability +/- 1% F.S., IP65 protection and 0.01NTU resolution, support USB connection and data storage.

$ 800.00

Using ultra-low power consumption single chip standby for up to 6 months, equipped with imported high stability Optical inspection system to achieve +/- 1% F. S Accuracy, IP65 protection design to ensure harsh environment reliability.

$ 637.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Using ultra-low power 16-bit microcontroller, standby time can reach more than 6 months; measurement range 0~ 1000NTU, repeability +/- 2% F.S; Equipped with imported high-luminance Illuminant and cold Illuminant narrow-band interference Optical inspection system to ensure Optical inspection stability; Molded ABS case, IP65 design, anti-corrosion, waterproof and dustproof.

$ 664.00

Measurement range 0-2μS/cm, suitable for ultra-low conductivity medium, support temperature compensation and a variety of installation scenarios to ensure Data Reliability.

$ 224.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

Adopt proportional refrigeration technology and high temperature direct drop technology, temperature fluctuation +/- 0.1 ℃, pump maximum Flow rate 22L/min, support short time idling and low liquid level protection, long service life.

$ 2136.00

The lower limit of measurement can be up to 1mPa · s, the sample volume is only 30ml, the rotor is easy to load and unload and the running state can be observed, which is convenient for cleaning and detailed analysis of rheological characteristics.

$ 315.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -80~ 40 ℃, cooling capacity 400W, built-in pressure suction pump, Flow rate 12L/min, support short time idling and impurity resistance.

$ 4677.00

Adopt stepper motor direct drive to ensure accurate speed, equipped with RTD temperature probe real-time monitoring, Measurement accuracy of +/- 1% F. S, with ultra-low viscosity adapter to extend Measurement range to 1mPa · s.

$ 1075.00

The use of non-heat centrifugal circulation pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, support 200 degrees of high temperature directly start cooling, domestic circulation system to achieve a high degree of uniformity in the flow field, to ensure a stable liquid environment.

$ 6902.00

Dedicated to 0.1~ 10mPa · s ultra-low viscosity liquid measurement, the sample volume is only 25ml, the cylinder rotor design can accurately calculate the shear rate, easy to sample detailed analysis.

$ 173.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.

$ 3151.00

Adopt non-heat centrifugal circulation pump to avoid its own heat pRoduction, Temperature Uniformity +/- 0.05 ℃, support 200 degrees high temperature direct start cooling without damaging the Compressor, equipped with 13L/min external circulation Flow rate to ensure stable insulation field.

$ 2671.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.