Aluminum Material ColoriMeter

The aluminum colorimeter projects a standard light source onto the surface of the aluminum material, measures the spectral data of the reflected light, and calculates the chromaticity coordinates and color difference values. It is used to monitor color consistency during aluminum production processes and to detect color differences in processes such as anodizing and spraying.
Selection
When selecting, consider matching the measurement aperture to the sample size. The instrument's repeatability should be less than 0.08 ΔE. Choose a model equipped with both specular reflection and UV filters. Check for compliance with the ASTM E1164 standard and select a model that supports multiple color spaces.

Terms

Standards

Instruments

Made of titanium anodic oxidation aluminum material, the filter diaMeter is 3mm, and the viscosity range of 7~ 42cSt can be measured. The hole design is sensitive to the outflow time, and special cleaning tools are required for maintenance.

$ 462.00

Using titanium anodic oxidation aluminum material to ensure durability, 5mm filter diaMeter covers 91~ 326cSt viscosity range, in line with ISO2431 standards, short channel design is sensitive to outflow time, requiring special cleaning tools to maintain.

$ 497.00

Using titanium anodic oxidation aluminum material, the filter is stainless steel, the diaMeter of the flow hole is 4.1mm, the viscosity range is 70-370cSt, the Cup mouth is designed with an anti-spill groove, and each Cup is engraved with a unique serial number.

$ 497.00

The highest temperature is 1400 ℃, the Furnace volume is 4.5L, and the aluminum oxide fiber Furnace and silicon carbon Rod heating elements are used to support the inert gas environment and ensure the uniform and stable sintering of the material.

$ 3720.00

Using aluminum material, hollow structure design, volume 50ml, in line with the national standard GB/T6750, suitable for density measurement, Balance hammer filled with lead particles to adjust the weight.

$ 106.00

Using titanium anodic oxidation aluminum material, flow hole diaMeter 4mm, Cup height 75mm, corrosion resistance and lightweight, each Cup engraved with an independent serial number to ensure accurate and reliable measurement.

$ 438.00

The non-swirl/spin sealing ring design ensures test sealing, equipped with a horizontal indicator and a width support ring for easy operation, the test area is 25cm ², the capacity is 40cm ³, and the anodic oxidation aluminum material guarantees durability and easy cleaning characteristics.

$ 606.00

Using titanium anodic oxidation aluminum material, filter diaMeter 6mm, viscosity measurement range 188~ 684cSt, in line with ISO2431 international standards, channel design is sensitive to outflow time, requiring special cleaning tools maintenance.

$ 465.00

Using high-quality aluminum alloy and stainless steel material, aperture 4.12mm, viscosity measurement range of 70~ 370cSt, flow time of 20~ 105 seconds, through the flow time to evaluate the liquid viscosity characteristics.

$ 130.00

Using titanium anodic oxidation aluminum material, filter diaMeter 8mm, applicable viscosity range 600~ 2000cSt, channel design is short, cleaning requires a fine brush and solvent to avoid scratches, to ensure measurement accuracy.

$ 509.00

Aluminum material, 37ml volume, in accordance with GBT21862 and ISO 2811 standards, the cover is designed with holes to facilitate excess liquid overflow, ensuring accurate measurement.

$ 120.00

Maximum temperature up to 1700 ℃, Furnace volume 36L, using aluminum oxide fiber material and silicon molybdenum Rod heating element, equipped with a chill down system to ensure sealing performance, support inert or reducing gas environment sintering.

$ 6851.00

Operating temperature up to 1700 ℃, Furnace volume 80L, aluminum oxide fiber Furnace and double chill down system, support inert and reducing atmosphere environment material sintering treatment.

$ 7867.00

Enclosed aluminum silicate Furnace and nickel-chromium-aluminum alloy heating wire are used to reduce volatile gas corrosion; three-sided heating method combined with PID control, Temperature Fluctuation +/- 5%, accurate and stable temperature control.

$ 1138.00

Using titanium anodic oxidation aluminum material to ensure durability, 4mm filter design supports 34~ 135cSt viscosity test, conforms to ISO2431 standard, provides High Accuracy and repeatability, easy cleaning and maintenance.

$ 465.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.