Ash Fusion Point Tester

The ash fusion point tester is used to determine the melting characteristics of ash in materials at high temperatures. The sample is heated according to a set temperature program, and the temperature points at which the ash begins to deform, form a hemisphere, and flow are determined by observing morphological changes or through image analysis. This instrument is used to evaluate the slagging tendency and process suitability of materials such as fuels and minerals under high-temperature conditions.
Selection
When selecting an ash fusion point tester, it is essential to consider that the maximum operating temperature meets the material testing range and that the heating rate is adjustable to comply with standard methods. The observation system must clearly display sample morphological changes, while the temperature measurement accuracy should meet regulatory requirements. The structural design should facilitate operation and maintenance, and the equipment dimensions must fit the laboratory space.

Terms

Standards

Instruments

Equipped with Sony 5 million pixel CMOS Sensor, supports global shutter and 35fps high-speed imagery, real-time image stitching and depth of field fusion functions to optimize the operation process and improve work efficiency.

$ 3268.00

Double-decked insulation Furnace shell to ensure that the shell is not hot, Furnace temperature distribution uniform, heating rate ≥ 10 ℃/min, with over-current, over-pressure, over-temperature and other multiple Safety protection, temperature control program can be customized settings.

$ 1227.00

Equipped with 20 million pixel Sony IMX183 Sensor and global shutter technology, support real-time image stitching and depth of field fusion, USB3.0 interface realizes 15fps high-speed transmission, providing a complete image acquisition to report output workflow.

$ 2139.00

Equipped with Sony IMX178 Sensor, 3072x2048 resolution, supports real-time image stitching and depth of field fusion functions, global shutter technology ensures distortion-free shooting of dynamic samples, and USB3.0 interface realizes 40fps high-speed imagery.

$ 1493.00

The double-decked Furnace shell structure ensures that the shell is not hot, the ceramic fiber Furnace cooperates with multi-sided heating to achieve uniform temperature distribution in the cavity, the heating rate is ≥ 10 ℃/min and the temperature control accuracy is +/- 2 ℃, and supports self-compiled temperature control programs and a number of Safety protection.

$ 964.00

Double-decked insulation Furnace shell to ensure that the shell is not hot, ceramic fiber Furnace with multi-sided heating to achieve uniform temperature distribution in the cavity. Heating rate ≥ 10 ℃/min, temperature control accuracy +/- 2 ℃, equipped with K-type Thermocouple and multiple Safety protection system.

$ 882.00

Temperature uniformity is less than +/- 5 ℃, heating rate is ≥ 10 ℃/min. With nitrogen filling device to slow down oxidation, double-decked Furnace shell insulation design to ensure that the shell is not hot, support self-made temperature control program.

$ 1238.00

Measurement accuracy of 0.5%, support 1-3 point Automatic calibration and automatic temperature compensation, can connect Bluetooth pH and dissolved oxygen Meter for Multi-ParaMeter measurement, provide end point lock and limit alarm function.

$ 230.00

Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.

$ 1719.00

Measurement accuracy of 0.5% F.S. with 1 to 3 point calibrating and automatic temperature compensation, Multi-ParaMeter measurement and Bluetooth connection are supported to ensure accurate data transmission and stable readings.

$ 230.00

Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.

$ 696.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.

$ 696.00

With 5 point button Adjustment, Measurement accuracy of 1% F. S, Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, equipped with USB interface for data transmission.

$ 696.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Articles

How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Muffle furnace is used for the determination of coating loss on ignition and ash content.
A muffle furnace is a laboratory heating device used to determine the loss on ignition and ash content of coating materials. By incinerating the sample at high temperatures, the organic components decompose and volatilize, leaving behind inorganic residues as ash.
Muffle Furnace Ash Test Method for Determination of Inorganic Filler Residues in Varnish
This article introduces the method of using the muffle furnace ash test to determine the residual amount of inorganic fillers in varnish. The inorganic substances in varnish can affect the performance of the coating, making accurate determination of ash content important for quality control.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Operation procedure of hot melt adhesive ash content determination instrument
This article introduces the operating procedures of a hot-melt adhesive ash content analyzer. The instrument incinerates the sample at high temperatures to decompose the organic components, leaving behind inorganic residues as ash. The ash content is then calculated based on the mass change before and after incineration.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.
Method for Determination of Ash Content in Paper
This article introduces the method for determining the ash content in paper. Ash refers to the inorganic residues left after the paper is burned at high temperatures, and its content affects the performance and processing of the paper.