High-Temperature & High-Humidity Environmental Chamber

The high-temperature and high-humidity test chamber simulates high-temperature and high-humidity environments by heating with electric heating tubes and generating steam with humidifiers. It is used to test the resistance of materials to heat and humidity aging, commonly applied in environmental adaptability inspections of electronic components, coatings, plastics, and other products.
Selection
When selecting, consider that the temperature range should cover the testing standards, humidity control accuracy should meet the requirements, the inner chamber material should be corrosion-resistant, the equipment size should match the sample volume, safety protection functions should be comprehensive, energy consumption should align with usage conditions, and after-sales maintenance should be convenient and reliable.

Terms

Standards

Instruments

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.

$ 4138.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.

$ 5110.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.

$ 14388.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.

$ 16459.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.

$ 6194.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% RH, with multi-stage programming and PID automatic calculation function, support data export and analysis, built-in safety alarm system to ensure stable operation.

$ 15374.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.

$ 8857.00

Temperature range -60~ 150 ℃, Humidity control accuracy +/- 3% R.H., non-fluorine environmental protection refrigerant and independent temperature limit alarm system, with multi-stage programmable control and Interface function.

$ 6983.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.

$ 1627.00

Articles

Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.
Differences and Selection Between Alternating Damp Heat and Constant Damp Heat Test Methods
Based on the patterns of humidity and temperature changes, they are mainly divided into two categories: constant damp heat tests and cyclic damp heat tests. Both simulate the effects of humid environments on products, but there are significant differences in their stress application methods, failure mechanisms, and applicable standards.