Laboratory Paint Mixing Machine

The laboratory paint mixer uses a motor to drive the blades in rotation, ensuring uniform mixing of paint components. It is used for the preparation of paint samples, color blending, and pretreatment before performance testing to ensure the consistency of experimental samples.
Selection
Select the corresponding power and speed range based on the viscosity of the coating; consider the compatibility of the container material with the mixing blades; pay attention to safety protection design and ease of cleaning; verify the match between sample capacity and machine specifications.

Terms

Standards

Instruments

Frequency of 710 vibrations per minute, mixing in 30 seconds; can handle 0.5 to 20 liters of barrel paint, equipped with safety interlock and height adjustment functions, quiet operation and easy loading.

$ 1364.00

Adopt all directions swing vibration mode to ensure that the paint is fully mixed, Vibration Frequency 550 times/min, equipped with 0-15 minute timing function, suitable for 80-240mm barrel height range.

$ 1171.00

The equipment supports 0.5-20 liters of barrel paint mixing, revolution speed 100-200rpm, rotation speed 200-400rpm, using multi-stage intelligent frequency conversion speed regulation and door opening and shutdown protection to achieve smooth operation and safe operation.

$ 2575.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

The device can quickly mix ground dispersed materials in a closed system, with a speed range of 1500-3500 rpm, a mixing capacity of 5-150G, and features bubble-free and quiet operation.

$ 6205.00

The non-contact mixing method is adopted to avoid sample contamination, the speed range is adjustable from 0 to 2800rpm, and various containers such as testtube beakers are supported. The mixing efficiency is dozens of times higher than that of manual mixing, and the mixing is uniform.

$ 127.00

Adopt closed system design, mixing capacity 5-200G, Speed range 1500-3500rpm, can achieve fast and efficient Mix & disperse, the operation process is quiet, pollution-free and bubble-free, support manual and intelligent two control modes.

$ 6851.00

Made of stainless steel, the diaMeter of the slurry is 60mm, and the diaMeter of the Rod is 8mm. It is suitable for efficient mixing of medium and low viscosity liquids. The structure is simple and durable, and the mixing effect is uniform and stable.

$ 96.00

High-performance explosion-proof motor, Power 750W, speed range 0-3000rpm, with multi-function dispersed ground mixing, closed design to reduce pollution, Modular structure for easy maintenance.

$ 1703.00

Impact height of 120 cm, hammer mass 1000g, no secondary rebound phenomenon after impact, punch diaMeter 16mm, can accurately determine the impact strength of the paint film.

$ 370.00

Mixing method of low speed intermittent sticking barrel edge, professional Impeller design, can be thoroughly stirred in 10 minutes without heating up, Speed range 0~ 50rpm adjustable, easy to replace stainless steel Mixing Tank.

$ 4592.00

High-performance motor running smooth and low noise, with CPU digital display dynamic Rotation speed control, can realize timing fixed speed operation, Processing capacity 10-100L, lifting Travel 600mm, support a variety of mixing forms simple replacement.

$ 1952.00

The adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel ≥ 80mm. The integrity of the paint film was evaluated by seven grades, and the operation was simple and conformed to the GB/T1720 standard.

$ 444.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.