Rapid Temperature Cycling Test Chamber

The rapid temperature cycle test chamber uses compressor cooling and electric heating tube heating to rapidly raise and lower the temperature within the chamber within a set range. It is used to simulate the tolerance of products in environments with temperature changes, detecting issues such as thermal expansion and contraction of materials, coating cracking, and component failure. It is widely applied in environmental adaptability testing for products such as electronic components, automotive parts, and plastic products.
Selection
When selecting, consider the size of the test sample to determine the inner chamber volume, determine the temperature range and rate of change based on the test standards, and pay attention to the compressor power and heater configuration. Note the insulation performance of the chamber and temperature uniformity, check the operation interface and program editing functions of the control system. Confirm the safety protection devices and ease of daily maintenance, and compare different brands and models within the budget.

Terms

Standards

Instruments

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Using 7.0 inch Touchscreen and French Taikang Compressor, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., with multi-wing air supply circulation and automatic calculation function to ensure uniform distribution of temperature and humidity and rapid stability.

$ 8545.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.

$ 25973.00

Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.

$ 9836.00

Using multi-channel mechanical compression refrigeration system and frequency conversion technology, energy consumption is reduced by 20%; with a linear temperature rise and fall rate of 15 ° C/min, Temperature Uniformity ≤ 2 ° C; through forced air duct system and special PID algorithm to achieve rapid temperature convergence and stability control.

$ 15210.00

With a linear temperature rise and fall rate of 10 ° C/min and a wide temperature range of -60 to 150 ° C, multi-channel refrigeration system and PID adaptive algorithm are used to achieve rapid temperature convergence, and environmentally friendly refrigerants and low noise design are equipped.

$ 18437.00

Multi-channel mechanical compression refrigeration system and adaptive throttling technology are used to achieve 5 ° C/min linear temperature rise and drop and +/- 0.5 ° C Temperature Fluctuation; equipped with PID adaptive algorithm and forced air duct system to ensure temperature uniformity and rapid convergence.

$ 15210.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure Temperature Uniformity ≤ 2 ° C, with remote monitoring function.

$ 28119.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and the PID adaptive algorithm is equipped to ensure that the Temperature Uniformity is ≤ 2 ° C, and the 512L studio meets the diverse testing requirements.

$ 31347.00

Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve rapid temperature change of 5 ° C/min; equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, support 120 groups of program editing and remote monitoring functions.

$ 20599.00

Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.

$ 13064.00

Temperature range -20~ 150 ℃, humidity control 30~ 98% R.H., stainless steel liner and ultra-fine Glass insulation cotton, equipped with independent over-temperature protection and multi-layer conductive film observation window to ensure stable and reliable testing.

$ 7771.00

Temperature range -30~ 150 ℃ and Temperature Uniformity ≤ +/- 2 ℃, using multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector and solid state relay control to ensure stable operation.

$ 7948.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, reduce energy consumption and noise through frequency conversion technology, and support 120 sets of program editing and remote monitoring functions.

$ 28119.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.