Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.
Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.
Measurement range is 0~ 199.9, Opacity of thin sheet material can be measured, Automatic calibration and Data storage function, Stability and repRoducibility are high, and system drift error is eliminated.
Adopting 45 °/0 ° illumination, the measurement area is about Φ 10mm, the Repeatability Standard Deviation is within Delta E * ab 0.5, and supports a variety of Color space display and statistical functions, making it easy to use.
Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.
Adopt 45 °/0 ° lighting mode, measurement diaMeter Φ 10mm, Repeatability Standard Deviation is within ≤ E * ab 0.5, support a variety of Color space display and statistical functions, automatic memory 99 sets of data.
Using dual 40 array Sensor and D/8 structure, SCI/SCE simultaneous measurement is supported, the test time is about 3.2 seconds, and the Repeatability Delta E * ab is controlled within 0.02, which is suitable for fluorescent samples and multiple Color Space analysis.
The 45/0 circular illumination geometry is used, and it is equipped with a dual measurement aperture of Φ 8mm and Φ 4mm. The chromatic value repeability is within Delta E * ab 0.03, and it supports the measurement of fluorescent samples and the calculation of various color difference formulas.
Using 45/0 Optical inspection structure and 256 pixel dual array CMOS sensor, Repeatability Delta E * ab is controlled within 0.02, supporting a variety of measurement diaMeters and fluorescent samples to ensure accurate and stable Color data.
Special sealing material is used to improve light protection, and the detection results are accurate and stable; the bottom detection design is not affected by the angle, and the data is reliable; the detection limit is less than or equal to 1.0 CFU/ml, and the repRoducibility is good, which is suitable for trace ATP analysis.
Special sealing material is used to improve light protection, and the test results are accurate and stable; the bottom detection design is not affected by the angle, and the data is reliable; the detection limit is less than or equal to 1.0 CFU/ml, the detection time is 1-60 seconds, and the integrated box is portable.
Special sealing material is used to improve light avoidance, and the detection results are accurate and stable; the bottom detection design is not affected by the angle; the detection accuracy reaches 1X10-16mol ATP, the detection range is 0-9999 RLU, and the integrated portable box design.
Optical inspection system and Modular design, equipped with flat-field color difference elimination fluorescent objective, fretting grid value of 2 μ m, support multi-band fluorescent filter group, comfortable operation.
Equipped with 254nm and 365nm dual-wavelength quartz ultraviolet lamps, support single or mixed use mode, integrated ordinary fluorescent lamp auxiliary lighting, the whole machine weighs only 3.7kg for easy operation and maintenance.
It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.