Powdered Coating Thickness Gauge

The powder coating thickness gauge measures coating thickness through magnetic induction or eddy current principles, with magnetic induction used for steel substrates and eddy current for non-ferrous metal substrates. It is used to detect the coverage thickness of sprayed powder on metal surfaces, ensuring coating uniformity, and is commonly employed in the quality control of metal product coating.
Selection
When selecting a powder coating thickness gauge, consider the substrate type: use magnetic induction for steel and eddy current for non-ferrous metals. Choose the measurement range based on the coating thickness, typically 0-2000 microns for general use. Portable models are suitable for on-site applications, while fixed ones are ideal for production lines. Ensure calibration standards and probe sizes are compatible with actual measurement needs.

Terms

Standards

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Measurement range of 5-500μm with a three-blade design, LED Illumination Microscope and swirl/spin system for accurate assessment of Coating thickness and substrate defects.

$ 296.00

Measurement range 0-3000μm, error +/- 3%, easy to carry and high Stability, suitable for a variety of Coating thickness detection.

$ 461.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Support multi-coating system measurement, can measure up to 3 Coating thickness, Measurement range 13~ 1000μm, error +/- (3% H + 2) μm, with 100000 data storage capacity and a variety of Data output methods.

$ 3462.00

Using eddy Current thickness measurement principle, equipped with ultra-thick coating special Probe, Measurement range 0~ 13000 μm, error +/- 3%, can read more than 180 data per minute, support 250,000 Measured value storage.

$ 1760.00

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Articles

High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Hall flowmeter measures the flowability of spray powder
This article introduces how a Hall flowmeter measures the flowability of spray powder. It uses a standard funnel to measure the time required for a certain mass of powder to flow out under gravity—the shorter the time, the better the flowability.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Pendulum hardness tester measures the damping hardness of powder coatings.
This article introduces the method of testing the damping hardness of powder coatings using a pendulum hardness tester. The test is based on the principle of energy attenuation, where the hardness is reflected by the time it takes for the amplitude of the pendulum to decay as it swings on the coating surface, with a longer time indicating a harder coating.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.