Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.
The Water-Cooled cooling system is adopted to ensure stable operation. The 395nm wavelength LED Illuminant provides uniform illumination. The light Power reaches 12W/cm ² and the illumination distance is 30-50mm. It has over-temperature protection and Power 0-100% adjustment function.
Using thread drive mechanism and bearing support, Angle Measurement range 0-45 °, Graduation 2.0 ′, test Rod weight 270g +/- 5g, repeability measurement can be averaged 9 times to ensure High Accuracy and Safety and Reliability.
Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.
Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.
Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.
Adopt titanium alloy shell to withstand strong acid and alkali environment, accurately cover 0-2 μ S/cm conductivity Measurement range, equipped with 1 Meter cable and G3 '/4 standard interface to achieve flexible installation of Reaction Kettle pipeline, 4 core interface to ensure stable signal transmission.
Platinum Sensor ensures fast and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 35mS/cm, Glass shell is durable, suitable for conventional liquid detection.
Using catalytic combustion Sensor, range 0~ 100% LEL adjustable, with automatic zero correction and temperature compensation function, Response Time does not exceed 60 seconds, support 4~ 20mA and RS485 output.
Fillable internal reference solution design with circular Glass sensitive membrane and annular ceramic liquid junction for low Conductivity Detector samples ensures measurement Stability and accuracy.
Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.