The dust density is measured by natural accumulation method, the diaMeter of the outflow port is 12.7mm, the funnel taper is 60 ° +/- 0.5 °, to ensure the stability of the free fall process, the volume of the measuringflask is 100mL, and the material is durable and easy to clean.
Adopt natural convection cycle to avoid sample volatilization, stainless steel liner is easy to clean, temperature control accuracy of +/- 0.5 ℃, optional multi-stage programming and independent temperature limit alarm system.
Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.
The natural convection cycle design ensures uniform temperature, temperature control accuracy of +/- 0.5 ℃, timing function up to 9999 minutes, suitable for drying, sterilizing and other applications.
Using natural convection design to ensure uniform temperature, Temperature range RT + 10~ 400 ℃, Temperature resolution 0.1 ℃, with timing function and multiple alarm system to ensure safe and reliable operation.
Temperature uniformity with natural convection design, temperature control accuracy of +/- 0.5 ° C, volume of 70L, independent temperature limit alarm system and timing function for 9999 minutes, suitable for a variety of drying sterilizing applications.
Using 60 ° taper funnel and 100ml standard glassgraduates with scale, the unit volume mass of the dust in the loose state was measured by free fall to ensure the accuracy and reliability of the test results.
Using natural convection cycle to avoid sample volatilization, Temperature range 10~ 200 ℃ and Fluctuation +/- 0.5 ℃, equipped with over-temperature protection and programmable function to achieve safe automatic operation.
140L large capacity studio, Temperature range RT + 10~ 400 ℃, Temperature Fluctuation +/- 0.5 ℃, natural convection design to ensure uniform temperature, timing function up to 9999 minutes, support Sensor fault alarm and over temperature protection.
304 stainless steel is used to ensure long-term use without rusting, equipped with 100ml standard glassgraduates with scale and 12.7mm outflow diaMeter funnel, and the unit volume mass of dust in the loose state is determined by free fall, which meets the requirements of national standards.
DC brushless motor drive, noise below 60dB, swing amplitude 8mm, soft start to avoid sample splashing, natural rubber platform acid and alkali corrosion, support RS232 Communication interface.
Speed range 3000 to 20000rpm, mixing tray for natural and synthetic LaTeX have different specifications, Operating temperature 10 to 40 ℃, can handle LaTeX pH value 1-14, to ensure stable operation.
Laser Sensor is used to directly measure the natural vibration frequency of the belt. Measurement range is 10-800Hz. The split probe size is 124 * 21 * 12mm and can penetrate into a small space of 66mm. It supports metric and imperial unit switching.
Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.
Laser Sensor is used to directly measure the natural vibration Frequency of the belt. Measurement range is 10Hz~ 800Hz. The size of the split Probe is only 124 * 21 * 12mm. It can penetrate into a small space of 66mm and supports metric and imperial Unit switching.