Micro-oscillating Balance

The micro-oscillation balance measures the mass of deposited particulate matter by monitoring the frequency changes of a quartz crystal oscillator. It is used for real-time monitoring of particulate matter concentration in ambient air and is commonly applied in atmospheric pollution source analysis and environmental monitoring stations.
Selection
When selecting, consider that the measurement range should cover local particulate matter concentrations, the sampling flow rate should match monitoring standards, the environmental temperature and humidity should adapt to on-site conditions, the maintenance cycle should align with operational needs, and data interfaces should be compatible with existing systems.

Terms

Standards

Instruments

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow star pan design, effectively reduce airflow and static interference, improve weighing accuracy and Stability.

$ 2171.00

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow pan design, effectively reduce airflow and static interference, improve weighing Stability.

$ 1848.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

Using electromagnetic force equilibrating Sensor, automatic timing internal calibrating to ensure accuracy, equipped with negative LCD screen, anti-static Glass and hollow star pan to improve weighing accuracy and Stability, support a variety of communication and printing functions.

$ 2494.00

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.

$ 267.00

Temperature control accuracy +/- 0.2 ℃, Temperature Uniformity ≤ +/- 0.3 ℃, DC brushless motor drive maintenance-free, with power-off automatic recovery and 0-100 hours timing function, support a variety of module replacement.

$ 908.00

Oscillation Frequency Range 300-3000rpm, Timed 5-120 minutes, Net weight only 1.2kg, suitable for micro Sample Handling, providing stable oscillation effect.

$ 133.00

Using electromagnetic force equilibrating Sensor, the highest accuracy of 0.01mg, dual range weighing range 210g/82g, built-in Automatic calibration and micro sample optimization function, Response fast and stable.

$ 2663.00

Using electromagnetic force equilibrating Sensor technology, the highest accuracy of 0.01mg, with dual range function, optimization of micro sample response, built-in Automatic calibration and a variety of weighing modes, transparent windshield design.

$ 2058.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.