Environmental Temperature and Humidity Detector

Environmental temperature and humidity detectors measure air temperature and humidity through sensors, converting physical quantities into electrical signals for display. They are used to monitor environmental conditions in places such as laboratories and warehouses, ensuring the stability of material storage and experimental processes.
Selection
When selecting, consider that the measurement range should cover the usage scenarios, and the accuracy should meet the requirements. Sensor types include capacitive hygrometers and thermistor thermometers. Pay attention to calibration cycles, data recording functions, and protection ratings. Choose a brand based on the budget.

Terms

Standards

Instruments

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.

$ 4138.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.

$ 5110.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.

$ 16459.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.

$ 14388.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.

$ 6194.00

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.

$ 8857.00

Temperature range -60~ 150 ℃, Humidity control accuracy +/- 3% R.H., non-fluorine environmental protection refrigerant and independent temperature limit alarm system, with multi-stage programmable control and Interface function.

$ 6983.00

Temperature range -60~ 150 ℃, humidity control 30~ 95% R. H; non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control function, support data export and remote monitoring, to ensure the accuracy and stability of the test process.

$ 13796.00

Temperature range -40~ 150 ℃ and Humidity control 30~ 95% RH, with multi-stage programming and PID automatic calculation function, support data export and analysis, built-in safety alarm system to ensure stable operation.

$ 15374.00

Temperature range -60~ 130 ℃, humidity control 30~ 95% RH, non-fluorine environmental protection refrigerant and imported Compressor, with multi-stage programmable control and independent temperature limit alarm system.

$ 7377.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with color Touchscreen and 100 sets of program presets, with independent temperature limit alarm and multiple Safety protection functions.

$ 14487.00

Environmental friendly refrigerant design, Temperature Uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with intelligent Touchscreen controller and multiple safety protection system to ensure stable and reliable experimental environment.

$ 3436.00

Articles

Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Xenon lamp aging test chamber evaluates the long-term outdoor performance of resins.
Xenon lamp aging test chambers simulate environmental conditions such as sunlight, temperature, and humidity to accelerate the testing of the weather resistance of materials like resins in a laboratory setting.
Key Operation Points of Carton Burst Strength Tester
The carton bursting strength tester is used to measure the maximum force that paperboard can withstand before rupturing under uniform pressure, which is important for packaging quality control. Before operation, ensure that the instrument is stable and the calibration is valid. The samples should be cut according to standards and conditioned under standard temperature and humidity conditions.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Analysis of the Influence of Temperature and Humidity on Paper Folding Endurance Testing
This article analyzes the impact of temperature and humidity on paper folding endurance testing. Paper folding endurance testing is typically conducted under standard temperature and humidity conditions, such as 23°C and 50% relative humidity.
Rapid prediction of coating chalking and gloss loss failure through UV aging tests.
This article introduces how UV aging tests can quickly predict the failure of paint chalking and loss of gloss. The test accelerates coating aging in the laboratory by simulating solar ultraviolet light, temperature, and humidity, while observing phenomena such as chalking and loss of gloss.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
UV aging test chambers are used for the aging evaluation of polymer materials.
The UV aging test chamber accelerates the aging process of polymer materials by simulating ultraviolet radiation from sunlight, combined with temperature and humidity control, to evaluate their durability.
How to Prepare Precise Film Layers Using a Laboratory Film Coating Machine
Precise film preparation can effectively eliminate human operational errors by rationally selecting applicators (wire rods or blades) that match the material's rheological properties and precisely controlling coating speed, environmental temperature and humidity, and substrate conditions.
Technical Selection and Application of Constant Temperature and Humidity Chambers
This article primarily discusses how to select and use a constant temperature and humidity chamber. It is mainly used to test the performance of materials and products under varying temperature and humidity conditions.