Ultra-Micro SpectroPhotoMeter

The ultra-micro spectrophotometer uses ultraviolet-visible light to irradiate a 1-2 μL sample and detects molecular absorbance. It is used for measuring nucleic acid and protein concentrations, suitable for rapid detection of micro-samples and avoiding the consumption associated with traditional cuvettes.
Selection
When selecting, pay attention to the sample volume range and detection limit, ensuring compatibility with the 260/280 nm nucleic acid/protein detection wavelength. Consider the type of sample carrier and ease of cleaning, and ensure the calibration method aligns with the laboratory's routine standard samples.

Terms

Standards

Instruments

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Speed range 5000 to 35000rpm, output power 120W, support stepless speed regulation, working head with SS316L material, maximum temperature 120 ℃, suitable for micro Sample Handling, with high linear speed and shear force.

$ 1243.00

Micro-gravure plate coating method to achieve ultra-thin uniform coating, Spreader thickness range is wide; integrated online corona treatment makes the substrate surface tension up to 72dyne/cm; drying box temperature control accuracy +/- 3 ℃ to meet different solvent drying needs.

$ 24279.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Large screen LCD graphic display, Wavelength range 325~ 1100nm, can accommodate 5~ 100mm Cuvette, support photometric detection and quantitative analysis, with Automatic calibration and ultra-low stray light, to ensure detection of linear Precision.

$ 929.00

Using Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can store 100 standard Linear dispersion and 200 data, supports a variety of Cuvette and direct printouts.

$ 1300.00

Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.

$ 267.00

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Speed range 5000~ 35000rpm, output power 120W, using SS316L stainless steel working head, providing high linear speed shear force, support micro Sample Handling and high viscosity medium.

$ 1177.00

Oscillation Frequency Range 300-3000rpm, Timed 5-120 minutes, Net weight only 1.2kg, suitable for micro Sample Handling, providing stable oscillation effect.

$ 133.00

Adopt Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can accommodate 5~ 100mm Cuvette, support a variety of Basis Weight test methods.

$ 1009.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 4.0nm, can accommodate 5~ 100mm Cuvette, support automatic wavelength calibration and Data storage.

$ 858.00

Equipped with a large screen LCD graphic display, can accommodate 5-100mm Cuvette, wavelength Precision +/- 0.3nm, with automatic wavelength Adjustment, supports multiple test modes including Light spectrum scanning and kinetic testing.

$ 1397.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Key Technical Points for Determining Arsenic and Mercury in Water Using Atomic Fluorescence Spectrophotometry
This article introduces the key techniques for determining arsenic and mercury in water using an atomic fluorescence spectrometer. The experiment requires attention to safety precautions, regular maintenance of the instrument, and proper disposal of waste liquids.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.