The phase transition process of samples can be detected by visual method, and three samples can be processed simultaneously and the average value can be calculated. Temperature range RT +~ 280 ℃, resolution 0.1 ℃, support 0.5-3 ℃/min four-speed heating rate, suitable for dark sample determination.
With visual and automatic dual measurement mode, to meet the needs of deep Color sample detection. Temperature resolution 0.1 ℃, can process three samples at the same time, support 0.1-10 ℃/min continuous adjustable heating rate.
Using photoelectric detection technology to automatically identify the initial and final melting points, equipped with Platinum Resistance Sensor to ensure +/- 0.5 ℃ accuracy, support eight linear heating rate and automatic storage function, no manual monitoring can complete the measurement.
Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.
Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.
It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.
High-resolution digital camera for automatic detection, can simultaneously measure 3 capillary tubing samples, Temperature range RT +~ 400 ℃, with automatic measurement and manual visual two functions, support data storage and export.
With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.
Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.
High-resolution digital camera to achieve automatic detection, can simultaneously measure five capillary tubing, temperature range RT +~ 400 ℃, with automatic measurement and manual visual measurement function, support multi-point calibrating and data export.
Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.
High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.
Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.
Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.
Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.