Line Glue Stick

The wire-wound rod is a coating tool that forms uniform gaps by winding stainless steel wires around the rod body, used for scraping liquid coatings or inks onto the surface of substrates. Its principle involves the transfer of liquid through the gaps between the wires and the rod body, creating a wet film of specific thickness. It is suitable for laboratory coating samples, ink printing tests, and the evaluation of coating uniformity on paper.
Selection
When selecting a wire-wound coating rods, the substrate surface characteristics and liquid viscosity should be considered. Large-diameter rods are suitable for rough surfaces, while high-viscosity liquids require models with wide gaps. Stainless steel materials resist solvent corrosion, and the rod length must match the coating width. The wire diameter specification determines the wet film thickness, and the gap value should be matched according to the testing standards.

Terms

Standards

Instruments

The instrument uses 241 +/- 6mm tire uniform rolling detection, wet film thickness 200um +/- 20um, every 30 seconds, repeability test, accurate determination of non-stick tire drying time, suitable for marking Coating quality control.

$ 231.00

The tire size of the instrument is Φ 241 +/- 6mm, weight 15.8 +/- 0.2kg, dedicated to marking Coating drying time test, easy to operate, accurate and reliable results.

$ 196.00

Using 470nm wavelength and double-sided LED Illuminant irradiation, equipped with amber filter and 105 * 163mm glue cutting area, accurate fluorescence sample separation operation can be achieved.

$ 201.00

Film Film thickness 22.9μm, Spreader width 30cm, wear-resistant stainless steel material, molding process, suitable for low viscosity glue and thermal glue experimental Spreader.

$ 186.00

Using double-sided LED Illuminant and 400nm wavelength, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which is convenient for accurate separation of fluorescently labeled nucleic acid protein samples.

$ 212.00

Using 365nm wavelength double-sided LED Illuminant, equipped with amber filter, the glue cutting area is up to 105 * 163mm, which can clearly observe the fluorescence and accurately separate the target area.

$ 223.00

The instrument is designed with a heavy hammer structure, with a weight mass of 6600g +/- 33g, which is suitable for the bending performance test of reflective film. It is simple to operate and safe and reliable to measure, and meets the requirements of national standards.

$ 522.00

The formed pRoduction process ensures that the film is uniform, the film thickness is 22.9μm, the application width is 300mm, which is suitable for low viscosity glue experiment, and the material is wear-resistant stainless steel to prolong the service life.

$ 167.00

Using 100LPI line number and quadrilateral pyramid hole structure, the transfer uniformity of inks is precisely regulated through hole shape and line number, which affects the wet film thickness and ensures the stability of ink supply.

$ 167.00

Using metal plating anilox roller, the number of lines can reach 180 lines/inch, which can precisely control the film fineness, and is suitable for the uniform Spreader test of inks Coating glue on various substrates.

$ 183.00

The metal plating anilox roller with 120 lines/inch quadrilateral pyramid mesh hole is used to achieve uniform Spreader with rubber roller, and the print width is 70mm, which is suitable for film effect testing of various liquid materials.

$ 183.00

Four-station independent operation, speed accuracy +/- 1% and range 100-7000rpm, support 5-stage program control and 3000 seconds homogenizing time, equipped with HEPA efficient filtrate to achieve 99.99% purification rate.

$ 8949.00

Using 6061 aluminum alloy heating platform and stainless steel cover plate, support 10 sets of formulations with a total of 320 procedures, each section is up to 9999 minutes, with the function of breaking couple alarm and over-temperature deviation alarm, Temperature Stability +/- 1%.

$ 1445.00

Measurement range 0~ 1500μm, accuracy +/- (5μm + 5%), stylus end angle of 60 degrees, suitable for surface profile measurement, with line design for easy connection.

$ 774.00

Water-Cooled cooling system, LED UV Illuminant with 395 nm wavelength and 700 W Power, Light intensity 0-100% adjustable, conveying speed 0-6 m/min adjustable, suitable for rapid curing of various UV materials.

$ 2284.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Comparison of Selection Between Dual-Column Gantry and Single-Column Universal Testing Machines for Plastic and Rubber Testing
This article compares the differences between dual-column portal and single-column universal testing machines in plastic and rubber testing. Dual-column portal types offer high rigidity and large load capacity, making them suitable for high-strength materials and high-precision testing; single-column types have an open structure and low cost, making them ideal for small loads and frequent fixture changes.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.