Four-unit Electric Stirrer for Laboratory

The laboratory four-head electric stirrer drives four independent stirring shafts to rotate synchronously through a motor, ensuring uniform mixing of liquids or slurries in the container. It is used for the preparation and reaction processes of samples such as coatings and inks, ensuring consistent material dispersion.
Selection
When selecting, consider the sample viscosity and capacity to match the motor power, choose the stirrer type based on the container shape, confirm the machine's heating configuration if temperature control is required, and ensure the operation interface is clear and easy for adjusting speed parameters.

Terms

Standards

Instruments

With +/- 0.5% FS accuracy and 0.001kgf resolution, support automatic conversion of Newton, kilogram, pound, gram four units, peak hold function can lock test MAX Maximum, 10 minutes automatic shutdown energy saving design.

$ 228.00

With +/- 0.5% FS accuracy and 0.01kgf resolution, support peak hold function, automatic shutdown and compatibility with battery and DC power supply to meet the needs of a variety of test environments.

$ 228.00

With ≤ 0.25% High Accuracy and 0-1000N Measurement range, supports four unit conversion and peak hold functions, suitable for different soil types detection.

$ 346.00

Features 0.5% FS accuracy and 0.01Kgf resolution, supports peak hold and four unit auto-conversion, dual display design for forward and reverse readings, Operating temperature range 0 ° C to 50 ° C.

$ 364.00

Four or six station design, each station independent control, Max. stirring Capacity 1500mL, stirring speed range of 100~ 2000rpm, brushless DC motor to provide stable drive.

$ 378.00

Using precision automatic control and data collection system, Force Indication Error ≤ +/- 0.5%, displacement accuracy ≤ +/- 0.05mm, support four test modes and 10,000 data storage, improve Test accuracy and operation convenience.

$ 2095.00

Four-station independent operation does not interfere with each other, the brushless DC motor provides 12.5mN · M torque, temperature control accuracy of +/- 1 ℃, supports automatic temperature control function and stepless speed regulation of 0~ 1500rpm, to meet the needs of multi-sample synchronous processing.

$ 569.00

Rotation speed 3000rpm, maximum linear speed 33m/s, high dispersion efficiency, strong material shear force, the formation of uniform suspension effect, safe and convenient operation, electric lifting fast fixed sealing barrel.

$ 2676.00

With 0.1~ 200000 Lux wide range, support Lux and FC dual unit measurement, with MAX Maximum hold and low voltage indication function, compact and portable.

$ 477.00

Driven by brushless DC motor, Max. stirring Capacity 1500mL, stirring speed adjustable 100~ 1500rpm, four stations can be operated independently to meet the needs of multiple groups of experiments synchronized.

$ 362.00

With Lux and FC dual unit measurement, Measurement range 0.01-2000 0Lux, support Bluetooth data transmission and MAX Maximum hold function, compact and easy to carry.

$ 525.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Electric lifting design is light and convenient, the highest Rotation speed 3000rpm, linear speed of 33m/s, double-end sealing structure to ensure vacuum sealing defoaming, suitable for viscosity ≤ 25000cps materials.

$ 2883.00

Using brushless DC motor to provide 500W output power and 100-1500rpm Speed range, equipped with electric lifting system up to Travel 500mm, with LCD real-time display and 0-9999 minutes timing function, support large capacity low medium and high viscosity material mixing.

$ 3849.00

Four stations can be independently controlled, Max. stirring Capacity 2L × 4, Speed range 50-1700rpm, with 40mN · M motor torque, support Continuous Operating Mode.

$ 377.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Key points for selecting a multi-factor comprehensive test chamber with integrated temperature, humidity, vibration, and altitude systems
The multi-factor comprehensive test chamber integrates four environmental stresses: temperature, humidity, vibration, and altitude (low pressure), used to simulate the reliability of products under complex environmental conditions.
Principles, Differences, and Application Selection Guide for 4 Common Laboratory Coating Machines
This article will delve into the working principles, technical distinctions, and typical applications of four core laboratory coating devices in laboratory settings.