Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.
ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.
Using ceramic variable capacitance sensing technology, repeatability error +/- 0.01g, with Ambient Temperature Compensation and overload protection functions, the structure is sturdy and durable.
Repeatability and accuracy are ensured with dual optical path sensing arrays and UV reinforced silicon photodiodes with 0.0001 resolution, 0-200% Transmittance Measurement range and support for APHA/PtCo, Gardner and Saybolt chroma scales.
Glass composite ElectRode and LT Glass sensing film, Measurement range 0-12pH, built-in temperature sensor automatic compensation, small design for micro sample detection, Bluetooth 4.0 technology implementation 10 Meters wireless transmission.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, copper ion type, capacity 480 ml, to ensure ElectRode performance stability and measurement accuracy.
ElectRode filling solution is suitable for ammonia Gas sensing electRode maintenance, providing bromine ion type and 480mL capacity to ensure stable ElectRode performance.
Using LT Glass sensing film, built-in temperature sensor, support Bluetooth 4.0 connection, transmission distance of 10 Meters, using CR2032 battery life of about 500 hours, suitable for micro vessel sample measurement.
The planar sensing structure can be directly bonded to curved and solid surfaces for measurement, with built-in 3mol KCl gel reference solution, Measurement range 0-14pH and 0-60 ℃, suitable for unconventional samples.
With a wide temperature measurement range of -18~ 1650 ° C, +/- 2% accuracy and 20:1 object distance ratio, Response Time 500ms, support for adjustable emissivity and Data storage functions, suitable for non-contact temperature monitoring.
The equipment temperature range -50~ 750 ℃, object distance ratio 12:1, Response Time 500ms, with non-contact measurement, High Accuracy and Fast Response characteristics, suitable for a variety of industrial scenarios.
250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.
With penetrating AISI 316 stainless steel Probe, easy to clean and insert semi-solid pRoducts. With CAL Check ™ boot self-check function, temperature accuracy of +/- 0.2 ℃, Measurement range covering -50.0~ 220 ℃.
Suitable for Ammonia Gas sensing electRode maintenance, capacity 480mL, Water Hardness Detection dedicated to ensure ElectRode performance stability, prolong service life.
ElectRode filling solution design, suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, to ensure long-term stable operation of ElectRode, improve measurement accuracy.