Wall Tile Chroma Meter

The wall tile colorimeter captures the reflected light from the surface through optical sensors and converts it into digital colorimetric values. It is used to measure the color consistency of wall tiles, control color differences in production, and is applied in tile manufacturing and quality inspection.
Selection
When selecting, consider matching the measurement aperture to the sample size, ensuring instrument repeatability for data stability, and compatibility with existing color management systems. Check the instrument's protection rating to suit the workshop environment and verify the validity of calibration certificates.

Terms

Standards

Instruments

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for large bottles such as wine bottles and infusion bottles.

$ 661.00

With bottle bottom and bottle wall double measurement function, test resolution of 0.001mm, no power supply, easy and fast operation, suitable for small volume bottles such as ampoules and vials, general structure design is simple and durable.

$ 622.00

Measurement principle of scattering-transmitted light, automatic chroma compensation, Measurement range 0~ 200.0NTU, Repeatability +/- 1% F. S, support multi-point calibrating and automatic range switching.

$ 767.00

With 0.001 NTU resolution and +/- 2% Repeatability, Chroma compensation system eliminates specimen Color interference, and Built-in Printer facilitates real-time data recording.

$ 465.00

High Accuracy measurement with 0.01 resolution, Chroma compensation system reduces Color interference, Built-in Printer facilitates data output, supports multi-point calibration to adapt to different ranges.

$ 703.00

With 0.001 NTU high resolution, chroma compensation function can eliminate sample Color interference, built-in real-time printing module, multi-point calibration to meet different range requirements, Stability error is only +/- 1.5%.

$ 812.00

Color interference is avoided by chroma compensation system, Measurement range 0-500NTU, resolution 0.01, Built-in Printer real-time printing data, High Accuracy optical path system to ensure long-term stability.

$ 515.00

Blue screen LCD module, Built-in Printer convenient data recording, increase the chroma compensation system to avoid Color interference, Measurement range 0-500NTU, resolution up to 0.001, zero drift +/- 1.5%, to ensure long-term stable work.

$ 557.00

Using LED Illuminant to provide stable 470nm wavelength, Measurement range 0-500PCU, accuracy +/- 10PCU, support NIST traceability standard calibrated to ensure the accuracy of water quality chroma detection.

$ 215.00

Blue LCD module and chroma compensation system are used to effectively avoid Color interference; Measurement range 0~ 200NTU, resolution 0.01; Built-in Printer is convenient for real-time printing, and unique positioning structure ensures long-term stable operation.

$ 399.00

The large diaMeter design is used to facilitate sample pouring in and out, the inner wall arc transition is easy to clean, and the accuracy is controlled within 0.2% to ensure reliable measurement results.

$ 117.00

Temperature range -40~ 150 ℃, Temperature Uniformity ≤ 2.0 ℃, mirror stainless steel inner wall and binary cascade refrigeration system, equipped with observation window and anti-condensation device.

$ 8687.00

Using aluminum alloy material, the accuracy is controlled within 0.2%, the inner wall arc transition is easy to clean, and the lid small hole design can overflow excess samples to avoid bubbles and improve the test accuracy.

$ 127.00

Using aluminum alloy material, the accuracy is controlled within 0.2%, the inner wall arc transition is easy to clean, and the lid hole design can overflow excess samples to avoid bubbles and improve the test accuracy.

$ 127.00

Adopt binary cascade refrigeration mode, temperature range -40 ℃ to 150 ℃, equipped with mirror stainless steel inner wall and automatic energy saving control system to ensure the test environment is stable and uniform.

$ 13044.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.