Measurement principle of scattering-transmitted light, automatic chroma compensation, Measurement range 0~ 200.0NTU, Repeatability +/- 1% F. S, support multi-point calibrating and automatic range switching.
With 0.001 NTU resolution and +/- 2% Repeatability, Chroma compensation system eliminates specimen Color interference, and Built-in Printer facilitates real-time data recording.
High Accuracy measurement with 0.01 resolution, Chroma compensation system reduces Color interference, Built-in Printer facilitates data output, supports multi-point calibration to adapt to different ranges.
With 0.001 NTU high resolution, chroma compensation function can eliminate sample Color interference, built-in real-time printing module, multi-point calibration to meet different range requirements, Stability error is only +/- 1.5%.
Measurement range 0-50 degrees, Indication Error no more than +/- 5%, Zero calibrated and fullness calibrated, direct reading without Reagent, IP65 Protection Rating and battery powered.
Color interference is avoided by chroma compensation system, Measurement range 0-500NTU, resolution 0.01, Built-in Printer real-time printing data, High Accuracy optical path system to ensure long-term stability.
Blue screen LCD module, Built-in Printer convenient data recording, increase the chroma compensation system to avoid Color interference, Measurement range 0-500NTU, resolution up to 0.001, zero drift +/- 1.5%, to ensure long-term stable work.
Using LED Illuminant to provide stable 470nm wavelength, Measurement range 0-500PCU, accuracy +/- 10PCU, support NIST traceability standard calibrated to ensure the accuracy of water quality chroma detection.
Blue LCD module and chroma compensation system are used to effectively avoid Color interference; Measurement range 0~ 200NTU, resolution 0.01; Built-in Printer is convenient for real-time printing, and unique positioning structure ensures long-term stable operation.
Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.
With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.
Using large sample Cuvette with excellent Optical inspection system, with chroma compensation and Illuminant automatic compensation function, Measurement accuracy up to +/- 2% + 0.02 NTU, Support automatic range conversion and a variety of Measurement modes.
Compact and easy to carry, resolution up to 0.01, Repeatability ≤ 0.02. Adopts dual light path design, supports three Standard light sources and multiple measurement calibers, and data can be stored in the cloud through the mobile phone Mini Program.
Adopt 0/d illumination geometry, Repeatability Delta E ≤ 0.2, equipped with 7-inch touchscreen, support data storage and a variety of color systems, suitable for reflection color measurement.
Measurement range 0-500mg/L, no reagents and digestion, 1-2 minutes rapid determination, built-in cold light source life of 100,000 hours, support a variety of data transmission methods.