Electric Heating Low Temperature Thermostat

The electric low-temperature thermostatic bath maintains a stable low-temperature environment in the liquid inside the tank through a combination of electric heating and refrigeration systems. It is used for low-temperature performance testing of materials, constant temperature control of chemical reactions, and instrument calibration, commonly found in laboratory sample preservation and physical property analysis.
Selection
When selecting, consider that the temperature range should cover experimental needs, temperature control accuracy should match testing standards, tank capacity should accommodate sample size, cooling power should ensure the rate of temperature decrease, while also paying attention to the corrosion resistance of the tank material and the operational stability of the equipment.

Terms

Standards

Instruments

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Equipped with powerful pressure suction pump to support peripheral groove thermostatic, Temperature Fluctuation is only +/- 0.1 ℃, pump flow 4L/min, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure sample safety.

$ 1389.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.

$ 877.00

Temperature range -30~ 100 ℃, Temperature Fluctuation +/- 0.1 ℃, equipped with strong pressure suction pump and external connection port, support over-temperature low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 2362.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, and the overall foaming and heat insulation performance of the low temperature Tank is good.

$ 1845.00

Rotation speed 3000rpm, maximum linear speed 33m/s, high dispersion efficiency, strong material shear force, the formation of uniform suspension effect, safe and convenient operation, electric lifting fast fixed sealing barrel.

$ 2676.00

Using high temperature non-alkali fiberglass insulation material sealing resistance wire, large heating area and heating fast, the highest temperature 380 ℃, support internal and external dual Sensor temperature measurement, no open flame design to avoid bumping Glass ware.

$ 170.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Mirror stainless steel liner and electric heating film heating, Temperature Uniformity +/- 1 ℃, heating speed, double-decked door design to reduce heat loss, four corners arc easy to clean.

$ 601.00

Using fuzzy PID controller to achieve accurate temperature control, Temperature Fluctuation +/- 0.5 ℃; Forced convection air duct system to improve Temperature uniformity; Mirror stainless steel liner with electric heating film heating, rapid and uniform heating; Independent temperature limit alarm to ensure experimental safety.

$ 992.00

Equipped with a strong pressure suction pump can provide a thermostatic source for the peripheral Tank, with a temperature accuracy of +/- 0.1 ° C, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 1098.00

Temperature range environment to 380 ℃, can work continuously, large heating area and rapid heating, effectively protect Glass ware.

$ 140.00

Electric lifting design is light and convenient, the highest Rotation speed 3000rpm, linear speed of 33m/s, double-end sealing structure to ensure vacuum sealing defoaming, suitable for viscosity ≤ 25000cps materials.

$ 2883.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor refrigeration, cooling fast low noise, the overall foaming performance of the Tank body is good, the inner Tank is made of stainless steel.

$ 2934.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.