High Temperature Resistance Muffle Furnace

The high-temperature resistance muffle furnace generates high temperatures through heating by resistance wires, and the furnace chamber is made of insulating materials to reduce heat loss. It is used for sample ashing, melting, heat treatment, etc., and is commonly found in ceramic sintering, metal heat treatment, and chemical analysis.
Selection
When selecting, consider that the maximum temperature must meet process requirements, the furnace chamber size must match the sample volume, the heating rate should align with the operational pace, the temperature control accuracy must comply with experimental standards, and attention should also be paid to power specifications and installation space.

Terms

Standards

Instruments

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

The maximum temperature is 1200 ℃, the Furnace volume is 2L, the microcomputer PID controller is used for precise temperature control, the door sealing design enhances Temperature uniformity, and the corrosion resistance refractory brick Furnace is durable.

$ 838.00

The maximum temperature can reach 1200 ℃, Furnace volume 7L, using microcomputer PID controller precise temperature control, refractory brick Furnace durable, Furnace door sealing design to enhance Temperature uniformity, safe and simple operation.

$ 1145.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

The refractory brick Furnace has good thermal insulation performance, volume 16L, maximum temperature 1200 ℃, temperature control accuracy +/- 2 ℃, with over-temperature alarm, power failure recovery and timing functions to ensure the safety and reliability of the experiment.

$ 1958.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.

$ 1046.00

High aluminum Furnace wear-resistant high temperature, 4-sided heating evenly; PID self-tuning temperature control accuracy +/- 2 ℃, over-temperature automatic protection; compact overall structure, convenient and safe operation.

$ 567.00

With 30 stages of multi-stage programmable control, the highest temperature 1200 ℃, Furnace volume 7L, using refractory brick Furnace and nickel-chromium wire heating elements, heat loss is small and Temperature uniformity is good.

$ 1392.00

Maximum temperature 1000 ℃, temperature control accuracy 1 ℃, using high aluminum liner and upper and lower left and right 4-sided heating design, with 30 program settings and over-temperature protection function, uniform temperature in the Furnace.

$ 893.00

With two-way door design to effectively prevent hot gas leakage, 30-stage multi-stage programmable control to achieve accurate temperature control cycle, Furnace Temperature uniformity and corrosion resistance, the maximum temperature 1200 ℃ Power 2.5KW.

$ 1046.00

Using ceramic fiber Furnace and air insulation structure, the surface temperature is only about 50 ℃. Heating to 1200 ℃ for less than 25 minutes, temperature control accuracy +/- 1 ℃, support multi-step program control.

$ 2048.00

Pottery and porcelain fiber liner with excellent thermal insulation performance, equipped with microcomputer P.I.D temperature controller temperature control accuracy of +/- 2 ℃, with over-temperature alarm and power failure recovery and other safety protection functions, Furnace volume 80L to meet a variety of experimental needs.

$ 6331.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Four-probe resistivity tester measures the sheet resistance of conductive polymer films.
This article introduces the method of measuring the sheet resistance of conductive polymer films using a four-probe resistivity tester. Sheet resistance is an important parameter for evaluating the conductivity of films.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.