With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.
With a 5/10 station design and room temperature range, multiple samples can be tested simultaneously, and the adhesion and durability performance can be accurately evaluated through the suspension weight measurement of the displacement or complete disengagement time.
Manual control of holding pressure is easy to operate, 15mm thick Organic Glass sealing bucket enhances compressire strength, Vacuum Level range -90~ 0kPa, resolution accurate to 0.1kPa, built-in time display automatic timing clear.
Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.
Provides irreversible temperature recording with accuracy of +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C. Self-adhesive design, resistant to oil, water and steam, ensures reliable monitoring.
Irreversible discoloration record historical temperature, accuracy +/- 1 ° C to +/- 4 ° C, oil, water and steam resistance, self-adhesive design for easy installation and storage.
Irreversible discoloration record temperature history, accuracy within 100 ° C +/- 1 ° C, oil and water vapor resistant, self-adhesive design easy to paste and remove, size 12 * 13mm, 50 sheets per copy.
Irreversible discoloration provides permanent temperature recording, Measurement accuracy +/- 4 ℃, oil resistance, water resistance and steam resistance, self-adhesive design for easy installation, Response instant no power supply, size 12 * 13mm compact and portable.
Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.
Irreversible discoloration design, temperature accuracy 50 ℃, circular single grid structure, specification 2x2cm, Pressure sensitive adhesive to ensure firm paste, suitable for temperature monitoring in harsh environments.
Three stations can be tested simultaneously, with a maximum time of 99 hours, 59 minutes and 59 seconds. Imported proximity switches and laser cross-cut test boards are used to ensure data accuracy and equipment durability.
Using 25 × 25mm ² 32 grid design, Glass plate thickness 1.2~ 2mm, through the standard Checkerboard test can accurately calculate the Coating hiding power, easy and fast operation.
Using irreversible discoloration technology, temperature measurement accuracy 55 ℃, specification 2x2cm circular design, with Pressure sensitive adhesive paste firmly, permanent discoloration after overheating is easy to identify, surface protective film enhances durability.
Measurement range 0~ 100, repeability accuracy 0.3%, Permissible Ambient Temperature 20 ° +/- 5 ° C, suitable for film hiding power testing.
10 station design can carry out multiple sets of tests at the same time. Temperature range RT +~ 250 ℃, hot air circulation to ensure uniform temperature. With over-temperature and electric overload automatic power-off protection, improve operation safety.