Water Iron Content Detector

The water quality iron content detector works by using chemical reagents to react with iron ions in water to produce color, and then uses a photometer to measure the color intensity to convert it into iron concentration. It is used to monitor iron levels in drinking water and industrial wastewater, helping to prevent pipeline corrosion and product contamination.
Selection
When selecting, consider that the detection range covers actual needs and the accuracy meets standard requirements. Ease of operation affects usage efficiency, while reagent consumption relates to operating costs. The instrument materials must be corrosion-resistant, and the supporting methods should comply with industry standards.

Terms

Standards

Instruments

Measurement range 0.00-5 mg/L, Color intensity is proportional to concentration, providing 100 tests, suitable for the analysis of iron content in various liquid samples.

$ 160.00

Using micro-processing technology and high Reliability integrated circuit, with data nonlinear processing and smoothing function, fast automatic multi-point correction, resolution of 0.001mg/L, Repeatability 2%, to ensure long-term stable work.

$ 356.00

Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.

$ 215.00

Supports iron-based and non-iron-based material measurement with accuracy of +/- 1~ 3% or +/- 2.5 µm, provides split Probe for enhanced maneuverability, automatically recognizes matrix materials and remembers calibrated values.

$ 527.00

With iron-based and non-iron-based dual-use function, resolution up to 0.1um, test range 0~ 1250um, support single and continuous measurement, automatic identification of matrix material, stable and portable operation.

$ 356.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Optical inspection Colorimetry is used to eliminate human error, the measurement resolution reaches 0.1mg/L, Repeatability ≤ 2%, suitable for all kinds of water urea content detection.

$ 309.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

Conductivity Detector measurement principle, measurement range 0~ 84%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation function, portable design weight only 203 grams.

$ 143.00

With manual and automatic temperature compensation function, Measurement range 0-6 PCL, resolution up to 0.01 PCL, easy operation and intuitive and accurate digital display, suitable for a variety of water quality monitoring scenarios.

$ 382.00

Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.

$ 99.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
Comparative Study of Lovibond Colorimeter and Iron-Cobalt Colorimeter
The Lovibond colorimeter and the iron-cobalt colorimeter are two widely used visual color measurement instruments in the industrial field. Both are designed based on the principle of standard color comparison, yet they exhibit significant differences in their specific implementation methods and application standards.