Air disturbance technology is used to simulate indoor air flow, equipped with 24 independent sample Chambers to prevent cross-contamination, the drying Temperature range is adjustable at RT-50 ° C, and the outer exhaust air is purified without affecting the environment.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Adjustable scraper Spreader mode, Spreader accuracy of +/- 0.02mm, equipped with air-cooled water-cooled double chill down system, Spreader rate of 5-25m/min, Heating Temperature range to 200 ℃ +/- 3 ℃.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Adopting pure oil-free piston design, equipped with a 4L gas storage Tank, the noise value is as low as 58dB, with an inner coating anti-rust treatment and a multi-stage filtrate system, the air pressure can be adjusted within the range of 5-8Bar, and the size is small and easy to install.
With 24 independent temperature control studios, Temperature range RT +~ 50 ℃, air disturbance technology and three-stage purification system are used to avoid cross-contamination of samples and improve drying efficiency.
Frequency range 20KHz to 100KHz, Sensitivity indicated by LED and sound, weight of only 140 grams for portable, suitable for a variety of gas and air leak detection scenarios.
Temperature range from room temperature to 60 ℃, temperature control accuracy +/- 1 ℃. Equipped with air purification device and exhaust gas treatment system to prevent cross-contamination and meet environmental standards.
The maximum pulling force is 15kN, the central aperture is 18mm, and it adopts a hollow self-resetting hydraulic cylinder and a digital pressure Gauge. It has the functions of peak holding and storage inquiry, making it suitable for on-site rapid detection.
The pure oil-free design ensures that the gas is free of oil pollution. The Power 3000w provides strong power, with noise as low as 62dB. It is equipped with 4 pump heads to improve exhaust efficiency. The air pressure can be adjusted within the range of 5 to 8 Bar to meet different needs.
Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.
Noise as low as 52 dB, pure oil-free design ensures zero gas pollution, equipped with 60L buffer Tank and electronic start-stop controller, providing stable air pressure output, suitable for a variety of industrial environments.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.