Touch-up Paint Coating Thickness Gauge

The repair paint coating thickness gauge measures the thickness of paint film on metal substrates non-destructively through magnetic induction or eddy current principles. It is used in automotive repair and industrial coating applications to monitor coating uniformity, ensuring repair quality and substrate protection.
Selection
When selecting, consider the substrate type (ferrous/non-ferrous metals), coating thickness range, measurement accuracy requirements. Handheld devices are suitable for on-site operations, probe size should match the workpiece shape, and calibration certificates and temperature compensation functions can enhance measurement stability.

Terms

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Support multi-coating system measurement, can measure up to 3 Coating thickness, Measurement range 13~ 1000μm, error +/- (3% H + 2) μm, with 100000 data storage capacity and a variety of Data output methods.

$ 3462.00

Measurement thicknesses up to 25mm with an error of only +/- 3% and a removable FJS Probe for thick protective coating measurements, supporting 1000 Data storage and statistical functions.

$ 1597.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

With paint penetration measurement ability, accurate measurement of wall thickness without removing coatings, thickness range 2.5~ 125mm, accuracy +/- 0.03mm, support multi-echo and single-echo mode switching, suitable for detection needs of different surface conditions.

$ 2739.00

Measurement range 25~ 3000μm, step tooth design Division 25μm to 200μm, can be quickly placed vertically on the coating surface to measure the thickness immediately.

$ 93.00

The extrusion pRoduction process ensures uniform coating application, with a wet film thickness of 38.9 microns and a coating precision of up to 0.1 microns. The stainless steel material ensures long-lasting durability, making it suitable for a variety of coating testing needs.

$ 160.00

Using ultrasonic technology nondestructive measurement, up to 3 layers of coating system measurement range 50~ 3800 μ m, error +/- 3%, with weatherproof design and high capacity Data storage function.

$ 3724.00

Battery-free, durable rare earth cobalt magnets, Measurement range 0 to 200 μm, accuracy +/- 1 µm (within 20 µm), with audible cues and wear-resistant carbide Probe.

$ 464.00

Suitable for high temperature surface measurement, the highest temperature up to 250 ℃, Measurement range 0~ 1000 microns, accuracy +/- (2μm + 3%), equipped with high contrast ratio color LCD screen, Data storage 1000.

$ 1721.00

It can prepare a wet film thickness of 13.7 microns, with a wire-wound design providing stable coating performance. The 9.52 mm diaMeter ensures easy operation, making it suitable for various paint application scenarios.

$ 167.00

Frequency 5.0MHz, support paint layer detection and emission to echo mode, Measurement range 2~ 160mm, suitable for a variety of workpiece thickness measurement.

$ 525.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.