Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.
Pure oil-free design ensures clean gas, exhaust volume of 1500L/min, automatic start and stop to reduce energy consumption, pressure dew point 2-10 ℃, suitable for a variety of industry needs.
With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.
With two sets of Compressor automatic switching, support for up to several months of uninterrupted operation; Illumrination degree 0~ 30000LX adjustable, CO2 concentration 0~ 10% monitoring; Programmable control of temperature Humidity and light to meet the needs of complex experiments.
With 30 stages of multi-stage programmable control, the highest temperature 1200 ℃, Furnace volume 7L, using refractory brick Furnace and nickel-chromium wire heating elements, heat loss is small and Temperature uniformity is good.
Equipped with microcomputer PID controller to achieve +/- 1 ℃ temperature control accuracy, 10 program programmable control to simplify the complex test process, Furnace door safety switch automatic power off to ensure safe operation.
Using multi-stage programmable PID controller, Temperature range -20~ 100 ℃, with independent temperature limit alarm system and P.I.D automatic calculation function, to ensure accurate and stable control of heat preservation Humidity, safe and reliable.
With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.
Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and 100 group program storage function.
Stepper motor is used to avoid voltage fluctuation affecting Rotation speed Stability, double abrasive wheels mesh friction design eliminates directional defects, and programmable control adapts to different test requirements.
Temperature range -60~ 130 ℃, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export and remote monitoring functions.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 120 groups of programmable control and independent temperature limit alarm system to ensure safe and accurate testing.
Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.
With two sets of imported Compressor automatic switching, support 0~ 40000LX Illumrination degree adjustment and CO2 concentration 0~ 10% monitoring, programmable control of 30-stage program and wireless alarm to ensure stable and reliable operation of the experiment.
Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.